• PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • BMS of LiFePO4 Battery Replacement for Lead-Acid Battery - PCM-L15S200-K79(Pre-charge/discharge)15S 200A

PCM-L15S200-K79(Pre-charge/discharge)15S 200A

BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

Model: PCM-L15S200-K79 
Working Current: 200A
Size: L250*W100*T18mm
Battery Type: Li-ion/LiFePO4
Battery Series: 15S

  • Description
  • Get quote
Sender email add: RE: PCM-L15S200-K79(Pre-charge/discharge)15S 200A
  • BMS of LiFePO4 Battery Replacement for Lead-Acid Battery

    Model:PCM-L15S200-K79
    No.  Test   item
    (Test at normal temperature 25±2℃ and relative humidity≤90%)
    Criterion 
    1 Communication Interface  RS485&UART
    CANBus&Bluetooth
    2 Voltage Charging voltage DC:51.75V~63V  CC/CV(3.45V~4.2V/Cell)15s
    Cell-balance detection voltage(Charge balance)                           can be adjusted by required
    Cell-balance detection delay time  0.5S—2S
    3 Current Balance current for single cell  32-58mA
    Normal operating-mode current (Gas Gauge IC) 600 uA(average)
    SLEEP operating-mode current (Gas Gauge IC) 350 uA(average)
    Maximal continuous charging current   30-200A
    Maximal continuous discharging current  30-200A
    4 Over charge Protection                       (single cell) Over charge detection voltage  3.6-4.35V
    Over charge detection delay time 0.5S—2S
    Over charge release voltage 3.4-4.15V
    5 Over discharge protection                  (single cell) Over discharge detection voltage 2.0-3.0V
    Over discharge detection delay time 150—300mS
    Over discharge release voltage 2.3-3.2V
    6 Over current protection(Battery pack)                    Over current detection current  90-600A
    Detection delay time   50ms—300ms
    Release condition  Cut load,Auto Recovery
    7 Short protection  Detection condition  Exterior short circuit  
    Detection delay time  200-800us
    Release condition  Cut load,Auto Recovery
    8 Resistance  Protection  circuitry  (MOSFET) ≤50mΩ
    9 Temperature  Operating Temperature Range  -40~+85℃
    Storage Temperature Range  -40~+125℃
    Pre-charge/discharge ,Optional  Heating Module
    SIZE: L250 *W100 *T18 mm
    NTC: 10K NTC                            Temperature switch:/                Weak current switch:YES                     Activation Method:/