PCM for 3S-4S RV-LF4S1P-10A(A-1)(4S) No Test item Criterion 1 Charging voltage DC:14.4V CC/CV Voltage Balance voltage for single cell 3.60V±0.025V 2 Balance current for single cell 120±10mA Current consumption for single cell ≤20μA Current Maximal continuous charging current 10A Maximal continuous Discharging current 10A 3 Over charge protection(single cell) Over charge detection voltage 3.90±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 3.8±0.025V 4 Over discharge protection(single cell) Over discharge detection voltage 2.0±0.062V Over discharge detection delay time 10—300mS Over discharge release voltage 2.0±0.062V 5 Over current protection Over current detection current 15±5A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery 6 Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load, Auto Recovery 7 Resistance Protection circuitry ≤20mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L150*W20
www.ayaatech.com
PCM for 10S-16S PCM-LX14S15A-AY200(LI-14S15A) Model: PCM-LX14S15A-AY200(LI-14S15A) Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 58.8V CC/CV(4.2v/Cell)14S Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤25uA Maximal continuous charging current 15A Maximal continuous discharging current 15A Balance current for single cell / Over-charge Protection(single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.50±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 45±5A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L257*W71*T6.5 mm NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L05S75-J49 No. Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:17.25V~21V CC/CV(3.45V~4.2V/Cell)5s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 20-75A Maximal continuous discharging current 20-75A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 60-220A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L130 *W116 *T8 mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S Model: PCM-LX01S06A-AY18650B Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 4.2V CC/CV(4.2V/Cell)1s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤7uA Maximal continuous charging current 8A Maximal continuous discharging current 8A Over-chargeProtection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over dischargeprotection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 20±5A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L18*W18*T2 mm NTC: / Temperature switch: / Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S Model: PCM-L16S100-F83 (LI-ION-16S100A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 67.2V CC/CV(4.2V/Cell)16S Capacity Designing battery capacity (PCM) /mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 100A Maximal continuous discharging current 100A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 1—3S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 300±50A Detection delay time 50-350mS Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L240*W120*T15 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-LB24S100A-AY233(LI-8S80A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 28.8V CC/CV(3.6V/cell) DC:33.6V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤50μA ≤50μA Max. continuous charging current 20A 80A Max. cont. discharging current 20A 80A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.1V 4.05 ±0.1V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-200mS 10-200mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-50ms 5-50ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 200~600us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L90*W65*T10mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Protection Circuit Module Specifications For 14.8V Li-ion/Li-Po Battery Pack Model: PCM-L04S35-E22 (4S) No. Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Charging voltage DC: 16.8V CC/CV(4.2V/1cell) 3 Capacity Designing battery capacity(PCM ) External capacity Indication LCD,LED Gas gauge algorithm IT (High accuracy) 4 Current Normal operating-mode current(Gas Gauge IC) 600 uA SLEEP operating-mode current(Gas Gauge IC) 200 uA Maximal continuous charging current 20A Maximal continuous discharging current 20A 5 Over charge Protection Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V 6 Over discharge protection Over discharge detection voltage 2.5±0.10V Over discharge detection delay time 0.5S—2S Over discharge release voltage 2.5±0.1V 7 Over current protection Over current detection current 70±10A Detection delay time 0.5S—2S Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load 9 Resistance Protection circuitry(MOSFET) ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Discharging Temperature Protection 65℃
www.ayaatech.com
PCM for 1S-2S PCM-L01S05-792(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L28*W10*T1.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 5S-9S PCM-Li05S8-002(B)(5S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 18VCC/CV(3.6V/cell) DC 21V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L80*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-LX4S10A-AY102(LI-4S10A) Model: PCM-LX4S10A-AY102(LI-4S10A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4S Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell / Over-charge Protection(single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.7±0.08V Over discharge detection delay time 50—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 30±5A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature Operating Temperature Range 0~+85℃ Storage Temperature Range 0~+125℃ SIZE: L50*W16*T4 mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-LB04S30-1506(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC 16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 30A 30A Max. cont. discharging current 30A 30A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model: PCM-L10S60-C05(LI-10S60A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C,Bluetooth Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 60A Maximal continuous discharging current 60A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L110*W91.5*T10mm NTC:10KNTC B=3435 Temperature switch:/℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S Model: PCM-Li4S5-068 (LI-4S4A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:50.4V CC/CV(4.2v/Cell)12s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤20uA Maximal continuous charging current 4A Maximal continuous discharging current 4A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.7±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 10±3A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature charge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L26 *W26 *T3 mm NTC: / Temperature switch: / Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S PCM-L16S15-582(16S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 57.6V CC/CV(3.6V/cell) DC:67.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 72±10mA 84±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L128*50*T12mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release voltage(V) 3.65±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-L04S15-E95 LI-4S 7A Model: PCM-L04S15-E95 (4S) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Capacity Designing battery capacity(PCM) / Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 12A Maximal continuous discharging current 12A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 30±5A Detection delay time 50ms—150ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W26*T4mm NTC: 10K Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model: PCM-L04S04-L31 Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBUS Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Capacity Designing battery capacity(PCM) /Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤800uA Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤350 uA Maximal continuous charging current 1A Maximal continuous discharging current 4A Balance current for single cell 56±10mA Over-charge Protection (single cell) Balance voltage for single cell 3.5±0.10V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) charge current protection 2±1A Detection delay time 0.5S—2S Discharge Over current protection1 12±1A Detection delay time 1S—3S Discharge Over current protection2 14±1A Detection delay time 0.5S—2S Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W55 *T9.5mm NTC:10K NTC Temperature switch: / ℃ (the batteries temperature) …
www.ayaatech.com
PCM for 3S-4S PCM-Li6530-037(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 10A 10A Max. cont. discharging current 10A 10A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W30mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-L05S06-338 (4S) Protection Circuit Module Specifications For 12.8V LiFePO4 Battery PackProtection Circuit Module Specifications For 14.8V Li-ion/Li-polymer Battery Pack Model:PCM-L05S06-338 (4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC14.4V CC/CV (3.6V/cell) DC:16.8V CC/CV (4.2V/cell) Balance voltage for single cell 3.6V±0.025V 4.2V±0.025V 2 Current Balance current for single cell 36±5mA; 42±5mA; Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection (single cell) Over charge detection voltage 3.9V±0.025V (optional) 4.35±0.025V (optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15±0.05V 4 Over discharge protection (single cell) Over discharge detection voltage 2.0±0.05V (optional) 2.4±0.08V (optional) Over discharge detection delay time 10-300mS 10-1000mS Over discharge release voltage 2.3±0.05V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load, Auto release Cut load, Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection …
www.ayaatech.com
PCM for 3S-4S PCM-LX4S5A-AY186(4S7A) Model: PCM-LX4S5A-AY186 ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 7A Maximal continuous discharging current 7A Balance current for single cell ※ / Over-charge Protection(single cell) Balance voltage for single cell ※ / Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.7±0.05V Over discharge detection delay time ※ 10—300mS Over discharge release voltage 3.0±0.1V Current protection (Battery pack) Discharge Over current detection current ※ 15±3A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection /℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L65*W48*T5 mm NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
Protection Circuit Module PCM-Li01S2A-2538(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6VCC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2A 2A Max. cont. discharging current 2A 2A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L25*W3.8*T2.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
PCM for 5S-9S PCM-L05S60-F91 LI-5S50A Model: PCM-L05S60-F91(5S) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:21V CC/CV(4.2v/Cell)5s Capacity Designing battery capacity(PCM) 5200mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 60A Maximal continuous discharging current 60A Balance current for single cell 68±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±20A Detection delay time 50ms—200ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W65*T11 mm NTC: / Temperature switch:90℃/65℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Fuel Gauge Model: PCM-L16S30-A44V1 (LI-16S10A ) BQ34Z100 Test Item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C Voltage Charging voltage DC: 67.2V CC/CV(4.2V/Cell) 16S Capacity Designing battery capacity(PCM ) /mAh Max capacity(Battery pack) 最大支持容量 8700mAh Min capacity(Battery pack) 最小支持容量 800mAh External capacity Indication 外部容量指示 FPC fuel gauge Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤160uA Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤80 uA Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤25uA Hibernate operating mode current:Fuel gauge in HIBERNATE mode.ILOAD < Hibernate Current 16 uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Over current protection Over current detection voltage 0.15v±0.025V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 70±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short …
www.ayaatech.com
PCM for 1S-2S PCM-L01S03-107(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L13.7*W13.57*T2.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-L04S30-1516(3S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.6+/-0.025V 4.2+/-0.025V 2 Current Balance current for single cell 36+/-5mA 42+/-5mA Current consumption for single cell ≤50μA ≤50μA Max. continuous charging current 30A 30A Max. cont. discharging current 30A 30A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W50*T5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L14S40-K77 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:48.3V~58.8V CC/CV(3.45V~4.2V/Cell)14s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 20-50A Maximal continuous discharging current 20-50A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 60-150A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L160*W65*T12mm NTC:10K NTC*3PCS Temperature switch:65℃&90℃ Weak current switch:/ Activation Method: /
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S30-A89(LI-2S30A) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:8.4V CC/CV(4.2v/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 100±20A Detection delay time 5ms—60ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W35*T6.5 mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S PCM-L16S30-922(16S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 57.6V CC/CV(3.6V/cell) DC:67.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±10mA 42±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 30A 30A Max. cont. discharging current 30A 30A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L120*65*T10mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release voltage(V) 3.65±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L16S100-H87(LF-16S) No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface I2C&Bluetooth 2 Capacity Designing battery capacity(PCM ) Max capacity(Battery pack) 100000mAh Min capacity(Battery pack) 800mAh External capacity Indication LCD,LED Gas gauge algorithm IT (High accuracy) 3 Voltage Charging voltage DC:57.6V CC/CV(3.6v/Cell)16s Cell-balance detection voltage(Charge balance) 3.6V±0.05V Cell-balance detection delay time 0.5S—2S 4 Current Balance current for single cell 116±10mA Normal operating-mode current (Gas Gauge IC) 600 uA SLEEP operating-mode current (Gas Gauge IC) 350 uA Maximal continuous charging current 100A Maximal continuous discharging current 100A 5 Over charge Protection Over charge detection voltage 3.75±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.50±0.1V 6 Over discharge protection Over discharge detection voltage 2.20±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 2.70±0.1V 7 Over current protection Over current detection current 300±50A Detection delay time 50ms—300ms Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load 9 Resistance Protection circuitry (MOSFET) ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Discharging Temperature Protection 65℃
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L04S30-G28+PCM-IICUART-E99 (LF-4S20A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Communication Interface RS232 Voltage Charging voltage DC:14.4V CC/CV(3.6V/Cell)4S Capacity Designing battery capacity(PCM) /mAh Max capacity(Battery pack) /mAh Gas gauge algorithm IT Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤600uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 36mA±10mA Over-charge Protection(single cell) Balance voltage for single cell 3.55V±0.025V Over charge detection voltage 3.90±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.50±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.00±0.07V Over discharge detection delay time 0.5S—2S Over discharge release voltage 2.50±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 40±10A Detection delay time 200-600us Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Discharge temperature detection delay time 5s high temperature discharge recover protection 45℃ high temperature charge protection 65℃ Charge temperature detection delay time 5s high temperature charge recover protection 45℃ Operating …
www.ayaatech.com
PCM for 5S-9S PCM-LX5S7A-AY041(LI-5S7A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 18V CC/CV(3.6V/cell) DC:21V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤50μA ≤50μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.1V 4.05 ±0.1V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-200mS 10-200mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-50ms 5-50ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 200~600us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L82*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L07S15-K39 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 5-15A Maximal continuous discharging current 5-15A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 15-45A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120 *W63 *T8 mm NTC: 10K NTC*2pcs Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-L06S10-554(6S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 21.6V CC/CV(3.6V/cell) DC:25.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L65*W36*T5.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L01S02-L41 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:3.45V~4.2V CC/CV(3.45V~4.2V/Cell)1s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 2-5A Maximal continuous discharging current 2-5A Balance current for single cell 36-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.20V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 6-12A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: ∮25*T3mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4SS PCM-L03C03-D13 LI-3S 3A Model: PCM-L03C03-D13 (3S) Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 12.6V CC/CV(4.2v/Cell)3s Capacity Designing battery capacity (PCM) / Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 3A Maximal continuous discharging current 3A Balance current for single cell / Over-charge Protection(single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 10±2A Detection delay time 50ms—150ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L18*W18*T3.8 mm NTC: 10K Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4SS PCM-Li04S4-011(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 4A 4A Max. cont. discharging current 4A 4A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L50*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 10S-16S Model: PCM-L10S25-B66(A)(LI-10S 15A)ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10s Capacity Designing battery capacity(PCM) / Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤150uA Maximal continuous charging current 5A Maximal continuous discharging current 25A Balance current for single cell 68±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 100±20A Detection delay time 100ms—300ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+70℃ Storage Temperature Range -40~+125℃ SIZE: L70*W36*T19 mm NTC: / Temperature switch:65℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-Li04S7-256(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC 16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L06S10-J15 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Cell-balance detection voltage(Charge balance) / Cell-balance detection delay time / 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 3-10A Maximal continuous discharging current 3-10A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 9-30A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L109 *W17 *T5 mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-Li04S8-016(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC: 16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L50*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
PCM for 10S-16S PCM-L10S20-858(A-1)(10S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 36V CC/CV(3.6V/cell) DC 42V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 20A 20A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
PCM for 10S-16S Protection Circuit Module Specifications For 48.1V Li-ion/Li-Po Battery Pack Model:PCM-L13S50-911(LI-13S) No. Test item Criterion 1 Voltage Charging voltage DC: 54.6V CC/CV (4.2V/1cell) Balance voltage for single cell 4.2V±0.025V 2 Current Balance current for single cell 85mA±5mA Current consumption for single cell ≤20μA Maximal continuous charging current 40A Maximal continuous discharging current 40A 3 Over charge Protection(single cell) Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.5±0.07V Over discharge detection delay time 10—30mS Over discharge release voltage 3.0±0.1V 5 Over current protection Over current detection voltage 0.2±0.015V Over current detection current 100±20A Detection delay time 5ms—20ms Release condition Cut load 6 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load 7 Resistance Protection circuitry (B- TO P-) ≤30mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Over Temperature protection (discharge) 60±5℃
www.ayaatech.com
PCM for 1S-2S PCM-L01S3-136(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 3A 3A Max. cont. discharging current 3A 3A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension Diameter=18mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-216(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L29.5*W6.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S Model: PCM-L04S10-187(LI-4S12A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 12A Maximal continuous discharging current 12A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.7±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 30±5A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L90 *W40 *T4.5 mm NTC: / Temperature switch: / Weak current switch:/
www.ayaatech.com
PCM for 5S-9S PCM-L06S12-520(6S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 21.6VCC/CV(3.6V/cell) DC 25.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 12A 12A Max. cont. discharging current 12A 12A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L64*W50*T4.6mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Protection Circuit Module Specifications For 12.8V LiFePO4 Battery Pack Model: PCM-L04S07-427 (4S) No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Charging voltage DC: 14.14V CC/CV(3.6V/1cell) 3 Capacity Designing battery capacity(PCM ) External capacity Indication LED Gas gauge algorithm IT (High accuracy) 4 Current Normal operating-mode current (Gas Gauge IC) 600 uA SLEEP operating-mode current(Gas Gauge IC) 200 uA Maximal continuous charging current 7A Maximal continuous discharging current 7A 5 Over charge Protection Over charge detection voltage 3.690±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 3.80±0.05V 6 Over discharge protection Over discharge detection voltage 2.0±0.10V Over discharge detection delay time 0.5S—2S Over discharge release voltage 2.5±0.1V 7 Over current protection Over current detection current 30±5A Detection delay time 0.5S—2S Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load 9 Resistance Protection circuitry(MOSFET) ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Discharging Temperature Protection 65℃
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB20S400A-AY306(LF-20S220A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:72V CC/CV(3.6v/Cell)20s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 220A Maximal continuous discharging current 220A Balance current for single cell 36±5mA Over-charge Protection(single cell) Balance voltage for single cell 3.6±0.05V Over charge detection voltage 3.85±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.65±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.3±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 800±100A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature charge protection / high temperature discharge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L175*W116.5*T18 mm NTC: / Temperature switch:/ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li01S8-015(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L32*W5*T2.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-LB16S100A-AY351(LI-4S80A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤50μA ≤50μA Max. continuous charging current 80A 80A Max. cont. discharging current 80A 80A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.05V(optional) 4.20±0.05V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.1V 4.25 ±0.1V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.05V(optional) Over discharge detection delay time 10-200mS 10-200mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-50ms 5-50ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 200~600us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L149*W80*T14mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S Model:PCM-L03C03-D13 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:10.35V~12.6V CC/CV(3.45V~4.2V/Cell)3s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 3A Maximal continuous discharging current 3A Over-charge Protection (single cell) Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 6-9A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L18*W18*T4mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li02S5-027(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33.5*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L16S200-F77(LI-16S200A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface CANBus,SMBus,HDQ,I2C,RS232,RS485 Voltage Charging voltage DC:67.2V CC/CV(4.2v/Cell)16S Capacity Designing battery capacity(PCM) No Limited Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 200A Maximal continuous discharging current 200A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L255*W115*T15mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li02S3-076(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC:7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33*W14.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
Smart Battery Managment with Fuel Guage Protection Circuit Module Specifications For 12.8V LiFePO4 Battery Pack Model:PCM-L04S100-G09 (LF-4S) No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Capacity Designing battery capacity(PCM ) mAh Max capacity(Battery pack) 100000mAh Capacity design multiple(Battery pack) 10 Times External capacity Indication LCD,LED Gas gauge algorithm IT (High accuracy) 3 Voltage Charging voltage DC: 14.4V CC/CV(3.6V/1cell) Cell-balance release voltage 3.6V ±0.025V Cell-balance detection delay time 0.5S—2S 4 Current Balance current for single cell 57±10mA Current self-consumption for single cell ≤30μA Normal operating-mode current self-consumption(Gas Gauge IC) 600 uA Low current self-consumption-mode (Gas Gauge IC) 350 uA SMBUS Communicating-mode current self-consumption(Gas Gauge IC) ≤2mA Bluetooth mode current self-consumption(Gas Gauge IC) ≤50mA Maximal continuous charging current 100A Maximal continuous discharging current 100A 5 Over charge Protection Over charge detection voltage 3.75±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.50±0.05V 6 Over discharge protection Over discharge detection voltage 2.20±0.05V Over discharge detection delay time 10—30mS Over discharge release voltage 2.50±0.05V 7 Over current protection Over charge detection current 150±20A detection delay time 2s Over current detection current 300±50A Detection delay time 5s Release condition Cut load, auro-release 8 Short …
www.ayaatech.com
BMS/PCM with Communications Model: AY-LX6S15A-T016 Ver: A BQ34Z100 Test item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C Voltage Charging voltage DC: 25.2V CC/CV(4.2V/Cell)6s Capacity Designing battery capacity (PCM) /Ah Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤200uA Low-power operating mode current: Fuel gauge in SLEEP mode. ILOAD < Sleep Current ≤130 uA Low-power operating mode current: Fuel gauge in FULLSLEEP mode. ILOAD < Sleep Current ≤12uA Maximal continuous charging current 12A Maximal continuous discharging current 12A Balance current for single cell / Over-charge Protection(single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.025V Over charge detection delay time 1S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.7±0.05V Over discharge detection delay time 1S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current1 40±10A Detection delay time 1S Discharge Over current detection current2 80±10A Detection delay time 100ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 180-300us Release condition Cut load Temperature Discharge temperature protection -10~+65℃ Charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: 52*34*6mm NTC: …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L01S05-H92 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:3.45V~4.2V CC/CV(3.45V~4.2V/Cell)1s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 2-5A Maximal continuous discharging current 2-5A Balance current for single cell 36-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.20V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 6-12A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L48*W5*T3mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-LB8S15A-AY026(8S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 28.8VCC/CV(3.6V/cell) DC:33.6V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L65*W40*T8mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
BMS/PCM with Communications Protection Circuit Module Specifications For 6.4V(2S) LI-ion Battery Pack Model: PCM-L02S05-D79(2S) No. Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Voltage Charging voltage DC:8.4V CC/CV(4.2V/1Cell) 2 Design Design Capacity mA 3 Current Current consumpion (software) <600 u A Current consumpion (sleep mode) <100 u A Maximal continuous charging current 5A Maximal continuous Discharging current 5A 4 Over Current Protection OCC1 Threshold 10000mA OCC1 Delay 2s OCC2 Threshold 12000mA OCC2 Delay 1s OCD1 Threshold 10000mA OCD1 Delay 2s OCD2 Threshold 12000mA OCD21 Delay 2s 5 Over charge protection COV Threshold Low Temp 4.25V±0.05V COV Threshold Standard Temp 4.25V±0.05V COV Threshold High Temp 4.25V±0.05V COV Threshold Rec Temp 4.25V±0.05V COV Delay 2S COV Recovery Low Temp 4.10V±0.05V COV Recovery Standard Temp 4.10V±0.05V COV Recovery High Temp 4.10V±0.05V COV Recovery Rec Temp 4.10V±0.05V 6 Over discharge Protection CUV Threshold 2.50V±0.05V CUV Delay 2S CUV Recovery 2.50V±0.05V CUVC Threshold 2.50V±0.05V CUVC Delay 2S CUVC Recovery 3.00V±0.05V 7 Over Temperature protection OTC Threshold +60℃±3℃ OTC Delay 2S OTC Recovery +55℃±3℃ OTD Threshold +60℃±3℃ OTD Delay 2S OTD Recovery +55℃±3℃ OTF Threshold +139℃±5℃ OTF Delay 2S OTF Recovery +139℃±5℃ UTC Threshold 0℃±3℃ UTC Delay 2S UTC Recovery 3℃±3℃ UTD Threshold …
www.ayaatech.com
PCM for 1S-2S PCM-L02S06-336(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC:7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.6V 4.2V 2 Current Balance current for single cell 36±5mA 42±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L40*W18*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S10-166 (LI-2S10A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV(4.2V/Cell)2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤10uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 20±5A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L51*W9*T2.5 mm NTC: / Temperature switch: Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB20S30A-AY024(LI-20S40A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 84V CC/CV(4.2v/Cell)20s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤20uA Maximal continuous charging current 5A Maximal continuous discharging current 40A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 120±30A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W63*T10 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L16S50-F34(LI-16S50A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface HDQ,I2C,Bluetooth Voltage Charging voltage DC:67.2V CC/CV(4.2v/Cell)16S Capacity Designing battery capacity(PCM) No Limited Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 50A Maximal continuous discharging current 50A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L250*W135*T10mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S PCM-LX10S20A-AY047(10S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 36V CC/CV(3.6V/cell) DC:42V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 20A 20A Max. cont. discharging current 20A 20A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W54.5*T7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S PCM-Li04S8-026(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L100*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model: AY-LB10S19A-T006 (LB-10S20A) Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBUS Voltage Charging voltage DC: 42V CC/CV(4.2V/Cell)10s Capacity Designing battery capacity(PCM) /Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤860uA Low-power operating mode current:Fuel gauge in SLEEP mode. ILOAD < Sleep Current ≤430 uA Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤12uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.30±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current 20±3A Detection delay time 0.5S—2S Discharge Over current detection current 850±10A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L90*W35*T7.5 …
www.ayaatech.com
PCM for 10S-16S Model: PCM-L10S15-A28(LI-10S15A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:42V CC/CV(4.2V/Cell)10S Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤100uA Maximal continuous charging current 15A Maximal continuous discharging current 15A Balance current for single cell 68mA±5mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.10V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.10V Over discharge detection delay time 10—200mS Over discharge release voltage 3.00±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 50±10A Detection delay time 1-60ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 1-10ms Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+70℃ Storage Temperature Range -40~+125℃ SIZE: L140*W26*T7.5 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications PCM-L08S08-953(LI-8S8A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 25.2VCC/CV(3.6V/cell) DC 29.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L100*W45*T6mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Fuel Gauge Model: AY-LB4S12A-T005-LB4S10A Model: AY-LB4S12A-T005-LB4S10A Ver: A Test Item (Test at normal temperature 25±2℃) Criterion Communication Interface SMBUS BQ40Z50 Voltage Charging voltage DC:16.8V CC/CV(4.2V/Cell)4s Capacity Designing battery capacity (PCM) 32Ah Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤160uA Low-power operating mode current: Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤80uA Maximal continuous charging current 12A Maximal continuous discharging current 12A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 30±5A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 20mΩ Temperature discharge temperature protection +65℃ charge temperature protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W35*T7mm NTC: 10KNTC B=3435 Temperature switch:/℃ (the batteries temperature) Weak …
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L10S20-E67(LI-10S20A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C,Bluetooth Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V ±0.05V Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L178*W62*T10mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-L04S10-178(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W28mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-LB2S15A-AY329 (LI-2S15A) Model: PCM-LB2S15A-AY329 (LI-2S15A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV(4.2V/Cell)2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 15A Maximal continuous discharging current 15A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection (Battery pack) Discharge Over current detection current 40±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L55*W20*T2.8 mm NTC: / Temperature switch:/ Weak current switch:/ special requirement: /
www.ayaatech.com
PCM for 5S-9S PCM-L07S10-811(7S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 25.2VCC/CV(3.6V/cell) DC 29.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 10A 10A Max. cont. discharging current 10A 10A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W60*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-078(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L30*W5.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 10S-16S Model: PCM-LB16S30A-AY087-LB16S30A ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 67.2V CC/CV (4.2v/Cell) 16S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell ※ 42±10mA Over-charge Protection(single cell) Balance voltage for single cell ※ 4.2V±0.05V Over charge detection voltage ※ 4.28±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 3.0±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.2±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 120±20A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L105*W65*T10 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:YES Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:AY-L10S15A-M051 No. Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&CANBUS 2 Voltage Charging voltage DC:34.5V~42V CC/CV(3.45V~4.2V/Cell)10s 3 Supply Current Normal operating-mode current (Gas Gauge IC) ≤25mA(average) SLEEP operating-mode current (Gas Gauge IC) ≤150uA(average) Maximal continuous charging current 10-20A Maximal continuous discharging current 10-20A Balance current for single cell 36-42mA 4 Over charge Protection (single cell) Balance voltage for single cell 3.6-4.2V Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over charge current protection 15-30A Detection delay time 1S Over current detection current 1 20-40A Detection delay time 2-5S Over current detection current 2 40-60A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L85 *W55 *T20 mm NTC: 10K NTC*2pcs Temperature switch:/ Weak current switch:/ Activation Method: /
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S15-K67 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:6.9V~8.4V CC/CV(3.45V~4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 5-15A Maximal continuous discharging current 5-15A Balance current for single cell 36-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.20V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 12-45A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W28*T4mm NTC:10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S Protection Circuit Module Specifications For 22.2V(6S)Li-ion Battery Pack Model: PCM-L06S07-849(6S) No. Test Item Criterion 1 Voltage Charging voltage DC:25.2V 4.2V/Cell Balance voltage for single cell 4.2±0.025V 2 Current Balance current for single cell 32±5mA Current consumption for single cell Max 20A Maximal continuous charging current 7A Maximal continuous Discharging current 7A 3 Over charge Protection Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.05V 4 Over discharge protection Over discharge detection voltage 2.50±0.062V Over discharge detection delay time 10mS—200mS Over discharge release voltage 2.50±0.062V 5 Over current protection Over current detection current 20±3A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery 6 Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load, Auto Recovery 7 Resistance Protection circuitry ≤20mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
PCM for 3S-4S Model: PCM-L04S16-761 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 5-20A Maximal continuous discharging current 5-20A Balance current for single cell 32-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.2V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 15-60A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: ∮52*T5mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-L03S06-337(3S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.6±0.05V 4.20±0.025V 2 Current Balance current for single cell 36±1mA 42±3mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L61*W25*T2.6mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 5S-9S PCM-L08S08-331(A1)(8S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 28.8V CC/CV(3.6V/cell) DC:33.6V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L72.5*W65*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S Model: PCM-L04S12-144(LI-4S10A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 25±5A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature high temperature discharge protection /℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: 40*40*3.5mm NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li2S5A-2807(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L28*W7*T2mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 5S-9S PCM-L05S06-338(5S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 18V CC/CV(3.6V/cell) DC 21V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L70*W33*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-L01S08-444(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L36*W7.5*T0.8mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB17S25A-AY068 ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 71.4V CC/CV(4.2v/Cell)17S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 25A Maximal continuous discharging current 25A Balance current for single cell ※ 42±10mA Over-charge Protection(single cell) Balance voltage for single cell ※ 4.2V±0.05V Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.5±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 200±50A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W65*T13 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:yes Activation Method: /
www.ayaatech.com
PCM for 1S-2S PCM-LB2S15A-AY07(LI-2S15A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.6+/-0.025V 4.2+/-0.025V 2 Current Balance current for single cell 36+/5mA 42+/-5mA Current consumption for single cell ≤10μA ≤10μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.30±0.05V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.10±0.1V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.4±0.05V(optional) Over discharge detection delay time 10-200mS 10-200mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-50ms 5-50ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 200~600us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L25*W7*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V 3.65±0.05V …
www.ayaatech.com
Smart Battery Managment with Fuel Guage PCM-G01S05-932 1S No Test item Criterion 1 Communication Interface I2C 2 Capacity Designing battery capacity (PCM) *mAh Max capacity(Battery pack) *mAh Min capacity(Battery pack) 8mAh External capacity Indication / Gas gauge algorithm Impedance Track 3 Voltage Charging voltage DC: 4.2V CC/CV(4.2V/1cell) Balance voltage for single cell / 4 Current Balance current for single cell / Normal operating-mode current:Gas Gauge in NORMAL mode,ILOAD > Sleep Current 140 uA SLEEP operating-mode current:Gas Gauge in SLEEP mode,ILOAD < Sleep Current 70 uA FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode,ILOAD < Sleep Current 25 uA Maximal continuous charging current 5A Maximal continuous discharging current 5A 5 Over charge Protection Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V 6 Over discharge protection Over discharge detection voltage 2.5±0.08V Over discharge detection delay time 10—1000mS Over discharge release voltage 3.0±0.1V 7 Over current protection Over current detection voltage 0.2±0.015V Over current detection current 12±5A Detection delay time 5ms—60ms Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200us-10ms Release condition Cut load 9 Resistance Protection circuitry ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature …
www.ayaatech.com
PCM for 5S-9S PCM-LX5S20A-AY043(LI-5S20A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 18V CC/CV(3.6V/cell) DC:21V CC/CV(4.2V/cell) Balance voltage for single cell 3.6+/-0.025V 4.2+/-0.025V 2 Current Balance current for single cell 36+/-5mA 42+/-5mA Current consumption for single cell ≤50μA ≤50μA Max. continuous charging current 20A 20A Max. cont. discharging current 20A 20A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.1V 4.05 ±0.1V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-200mS 10-200mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-50ms 5-50ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 200~600us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L90*W42*T9mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 3S-4S Model: PCM-L03S04-730 (LI-3S4A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:12.6V CC/CV(4.2v/Cell)3s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 4A Maximal continuous discharging current 4A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 4.35±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.40±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 10±3A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature charge protection / high temperature discharge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L32 *W32 *T3.5 mm NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB21S40A-AY327(LI-21S40A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 88.2V CC/CV(4.2v/Cell)21s Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 40A Maximal continuous discharging current 40A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.00±0.1V Current protection(Battery pack) Detection delay time 0.5~2.0S Discharge Over current detection current 120±30A Detection delay time 5ms—150ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 450~800uS Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature Operating Temperature Range -40~+70℃ Storage Temperature Range 0~60℃ Charging high temperature protection 50±5℃ Discharge high temperature protection 70±5℃ SIZE: L80*W60*T16 mm NTC: 10K NTC cut off Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-LX01S3A-AY245(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 1A 1A Max. cont. discharging current 1A 1A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L18*W18*T2mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-LX2S2A-AY321 (LI-2S2A) Model: PCM-LX2S2A-AY321 (LI-2S2A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV (4.2V/Cell) 2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤10uA Maximal continuous charging current 2A Maximal continuous discharging current 2A Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 100—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 5±2A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L34*W17*T3 mm P+/P- 2 contacts on top 12mm diameter “hard gold” NTC: / Temperature switch: / Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S06-H91 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:6.9V~8.4V CC/CV(3.45V~4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 3-10A Maximal continuous discharging current 3-10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 8-25A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L55*W7.45*T3mm NTC:10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:AY-L5S20A- M057 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&CANBUS 2 Voltage Charging voltage DC:17.25V~21V CC/CV(3.45V~4.2V/Cell)5s 3 Supply Current Normal operating-mode current (Gas Gauge IC) ≤25mA(average) SLEEP operating-mode current (Gas Gauge IC) ≤150uA(average) Maximal continuous charging current 10-20A Maximal continuous discharging current 10-20A Balance current for single cell 36-42mA 4 Over charge Protection (single cell) Balance voltage for single cell 3.6-4.2V Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over charge current protection 15-30A Detection delay time 1S Over current detection current 1 20-40A Detection delay time 2-5S Over current detection current 2 40-60A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L80 *W60*T20 mm NTC: 10K NTC*2pcs Temperature switch:/ Weak current switch:YES Activation Method: /
www.ayaatech.com
PCM for 3S-4S PCM-LB4S50A-AY196(LI-4S35A) Model: PCM-LB4S50A-AY196(LI-4S35A) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 35A Maximal continuous discharging current 35A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 70±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature high temperature discharge protection 60℃ Discharge temperature detection delay time 2s high temperature discharge recover protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L136*W32*T5 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-L08S08-953(LI-7S5A) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 25.2VCC/CV(3.6V/cell) DC 29.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L100*W45*T6mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 10S-16S Protection Circuit Module Specifications For 36V(10S)Lithium iron Phosphate Battery Pack Model: PCM-L10S10-B70 (10S 20A) No. Test Item Criterion 1 Voltage Charging voltage DC: 42V CC/CV Balance voltage for single cell 4.20±0.05V 2 Current Balance current for single cell 67±10mA Current consumption for single cell ≤20μA Maximal continuous charging current 20A Maximal continuous Discharging current 20A 3 Over charge Protection Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5—2S Over charge release voltage 4.01±0.1V 4 Over discharge protection Over discharge detection voltage 2.50±0.1V Over discharge detection delay time 0.2S—1S Over discharge release voltage 3.0±0.1V 5 Over current protection Over current detection current 70±10A Detection delay time 5ms—60ms Release condition Cut load, Auto Recovery 6 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load, Auto Recovery 7 Resistance Protection circuitry ≤30mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
BMS/PCM with Fuel Gauge Model: AY-LB7S10A-T004-LB7S10A Ver: A Test Item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C BQ34Z100 Voltage Charging voltage DC:29.4V CC/CV(4.2V/Cell)7s Capacity Designing battery capacity(PCM) 10Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤160uA Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤80uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell 84±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.28±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 3.0±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.2±0.1V Current protection(Battery pack) Discharge Over current detection current 50±10A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 20mΩ Temperature Temperature protection +65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L100*W65*T8mm LED SIZE: 30*16*3 (6) NTC: 10KNTC B=3435 Temperature switch:/℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
Smart Battery Managment with Fuel Guage PCM-L10S10-914 No Test item Criterion 1 Voltage Charging voltage DC: 42V CC/CV(4.2V/1cell) Balance voltage for single cell 2 Current Balance current for single cell Current consumption for single cell ≤20μA Maximal continuous charging current 12A Maximal continuous discharging current 12A 3 Over charge Protection(single cell) Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.5±0.07V Over discharge detection delay time 10—30mS Over discharge release voltage 3.0±0.1V 5 Over current protection Over current detection voltage 0.2±0.015V Over current detection current 35±5A Detection delay time 5ms—20ms Release condition Cut load 6 Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load 7 Resistance Protection circuitry(B- TO P-) ≤30mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ Over Temperature protection(discharge) 60±5℃ 9 Dimension L90*W50*T6mm
www.ayaatech.com
CV243 LI-2S IC:R5460N214AF+BQ27210 No Test item Criterion 1 Communication Interface HDQ or I2C 2 Capacity Designing battery capacity (PCM) *mAh Max capacity(Battery pack) *mAh Min capacity(Battery pack) \ External capacity Indication \ Gas gauge algorithm Impedance Track 3 Voltage Charging voltage DC: 8.4V CC/CV(4.2V/1cell) Balance voltage for single cell 4.20±0.05V 4 Current Balance current for single cell 116±10mA Normal operating-mode current:Gas Gauge in NORMAL mode,ILOAD > Sleep Current 160 uA SLEEP operating-mode current:Gas Gauge in SLEEP mode,ILOAD < Sleep Current 80 uA FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode,ILOAD < Sleep Current 25 uA Maximal continuous charging current 4A Maximal continuous discharging current 4A 5 Over charge Protection Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V 6 Over discharge protection Over discharge detection voltage 2.5±0.08V Over discharge detection delay time 10—1000mS Over discharge release voltage 3.0±0.1V 7 Over current protection Over current detection voltage 0.2±0.015V Over current detection current 12±2A Detection delay time 5ms—60ms Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200us-10ms Release condition Cut load 9 Resistance Protection circuitry ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
PCM for 3S-4S Model:PCM-L03S07-B29 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:10.35V~12.6V CC/CV(3.45V~4.2V/Cell)3s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 4-7A Maximal continuous discharging current 4-7A Over-charge Protection (single cell) Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 12-21A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L51.5*W16*T3mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
Model: PCM-LB16S100A-AY279(LI 16S100A) No Test item Criterion 1 Communication InterfaceAMBUS SMBUS or CANBUS or RS485 2 Capacity Max capacity(Battery pack) 10000000*mAh Min capacity(Battery pack) 1*mAh Designing battery capacity(PCM) *Ah 8% Estimation error ≤2% 3 Voltage Charging voltage DC: 67.2V CC/CV(4.2V/1cell) Balance voltage for single cell 4.20±0.05V 4 Current Balance current for single cell 42±10mA Normal operating-mode current:Gas Gauge in NORMAL mode,ILOAD > Sleep Current ≤30mA SLEEP operating-mode current:Gas Gauge in SLEEP mode,ILOAD < Sleep Current 80 uA FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode,ILOAD < Sleep Current 25 uA Maximal continuous charging current 100A Maximal continuous discharging current 100A 5 Over charge Protection Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V 6 Over discharge protection Over discharge detection voltage 2.5±0.08V Over discharge detection delay time 10—1000mS Over discharge release voltage 3.0±0.1V 7 Over current protection Over current detection voltage 0.2±0.015V Over current detection current 200±1% Detection delay time 5ms—60ms Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200us-10ms Release condition Cut load 9 Resistance Protection circuitry ≤50mΩ 10 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
PCM for 1S-2S PCM-L02S20-265V1 (LI-2S20A) Model: PCM-L02S20-265V1 (LI-2S20A) Ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:8.4V CC/CV(4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current 50±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W37*T4 mm NTC: / Temperature switch:/ Weak current switch:/ special requirement: /
www.ayaatech.com
BMS/PCM with Communications Model: AY-LB8S5A-T003 Ver: A Test item(Test at normal temperature 25±2℃) Criterion Communication Interface I2C Voltage Charging voltage DC:33.6V CC/CV(4.2V/Cell)8s Capacity Designing battery capacity(PCM) 5.4Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤160uA Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤120 uA Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤80uA Maximal continuous charging current 8A Maximal continuous discharging current 8A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current 15±3A Detection delay time 0.5S—2S Discharge Over current detection current 15±3A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60.3*W40*T7 mm NTC: 10KNTC B=3435 …
www.ayaatech.com
PCM for 1S-2S PCM-L02S10-881(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC 8.4V CC/CV(4.2V/cell) Balance voltage for single cell 2 Current Balance current for single cell Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V 3.65±0.05V Over discharge …
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB21S100A-AY316(LI-21S100A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 88.2V CC/CV(4.2v/Cell)21s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 100A Maximal continuous discharging current 100A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 500~1500mS Over discharge release voltage 3.00±0.1V Over current protection Over charge current detection current 120±20A Detection delay time 300~800mS Over discharge current detection 300±50A Detection delay time1 50~150mS Detection delay time2 5~15mS Short protection Release condition Cut load, Auto Recovery Detection condition Exterior short circuit Detection delay time 300~800mS Resistance Main loop electrify resistance ≤20mΩ Temperature Charging high temperature protection 50±5℃ Charging low temperature protection 0±5℃ Discharge high temperature protection 70±5℃ Discharge low temperature protection -20±5℃ Operating Temperature Range -20~+70℃ Storage Temperature Range 0~+60℃ SIZE: L120*W65*T16 mm NTC: 10K NTC/ 65℃ Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB24S150A-AY072 ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 100.8V CC/CV(4.2v/Cell)24s Capacity Designing battery capacity(PCM) *mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 150A Maximal continuous discharging current 150A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 450±50A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -20~+70℃ Storage Temperature Range -40~+125℃ SIZE: L125*W63*T15 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB20S170A-AY063 (21S170A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 88.2V CC/CV(4.2v/Cell)21S Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 170A Maximal continuous discharging current 170A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 0.5—1.8S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 500±100A Detection delay time 0.5s—1.5s Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection / Operating Temperature Range -20~+85℃ Storage Temperature Range -40~+125℃ SIZE: L174*W157*T13 mm NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/
www.ayaatech.com
PCM for 3S-4S PCM-LB4S80A-AY143 (LF-4S80A) Model: PCM-LB4S80A-AY143 (LF-4S80A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:14.4V CC/CV(3.6V/Cell)4s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 80A Maximal continuous discharging current 80A Balance current for single cell 36±10mA Over-charge Protection(single cell) Balance voltage for single cell 3.6V±0.05V Over charge detection voltage 3.9±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 3.8±0.025V Over discharge protection(single cell) Over discharge detection voltage 2.0±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.50±0.05V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 250±30A Detection delay time 10ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 100-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65±10℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L135*W95*T8.5 mm NTC: / Temperature switch:/ Weak current switch:/
www.ayaatech.com
PCM for 10S-16S Model: PCM-LB10S15-288V1 ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 5A Maximal continuous discharging current 15A Balance current for single cell ※ 42±10mA Over-charge Protection(single cell) Balance voltage for single cell ※ 4.2V±0.05V Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.05±0.1V Over dischargeprotection(single cell) Over discharge detection voltage ※ 2.5±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 40±5A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L70*W60*T11 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L10S30-A32(LI-10S30A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L90*W70*T16 mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L08S60-K38 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface I2C&Bluetooth 2 Voltage Charging voltage DC:27.6V~33.6V CC/CV(3.45V~4.2V/Cell)8s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 20-60A Maximal continuous discharging current 20-60A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 60-180A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L136 *W80 *T11 mm NTC: 10K NTC*2pcs Temperature switch:65℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S Model: PCM-L01S03-L07 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:3.45V~4.2V CC/CV(3.45V~4.2V/Cell)1s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 1-3A Maximal continuous discharging current 1-3A Balance current for single cell 36-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.20V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 3-9A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: ∮14*T3mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB20S150A-AY065(LI-20S 150A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 84V CC/CV(4.2v/Cell)20S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 20A Maximal continuous discharging current 150A Balance current for single cell ※ 42±10mA Over-charge Protection(single cell) Balance voltage for single cell ※ 4.2V±0.05V Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.8±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 500±100A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L200*W110*T19 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-L07S08-747(7S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 25.2VCC/CV(3.6V/cell) DC 29.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L64*W41*T5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V 4.05±0.05V …
www.ayaatech.com
PCM for 1S-2S PCM-Li2S3A-4408(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 3A 3A Max. cont. discharging current 3A 3A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L44*W8*T2mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L14S200-J51 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS&Bluetooth 2 Voltage Charging voltage DC:48.3V~58.8V CC/CV(3.45V~4.2V/Cell)14s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 50-200A Maximal continuous discharging current 50-200A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 200-600A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L225 *W140 *T14.5 mm NTC: 10K NTC*3pcs Temperature switch:/ Weak current switch:YES Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-LB20S400A-AY306(LF-4S300A) Model: PCM-LB20S400A-AY306(LF-4S300A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:14.4V CC/CV(3.6v/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 300A Maximal continuous discharging current 300A Balance current for single cell 36±5mA Over-charge Protection(single cell) Balance voltage for single cell 3.6±0.05V Over charge detection voltage 3.85±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.65±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.3±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5±0.1V Current protection (Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 800±100A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature charge protection / high temperature discharge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L175 *W116.5*T18 mm NTC: / Temperature switch:/ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S Model: PCM-L16S25-591(Li-16S20A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:67.2V CC/CV(4.2V/Cell)16S Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 68±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.025V Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.50±0.07V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 80±10A Detection delay time 200-600us Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L78*W55*T18mm NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model: AY-LX3S1.5A-T002-LB3S1.5A Ver: A Test item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C Voltage Charging voltage DC:12.6V CC/CV(4.2V/Cell)3S Supply Current Normal operating mode Self consumption current ※ ≤ 30uA Maximal continuous charging current 2A Maximal continuous discharging current 2A Over-charge Protection(single cell) Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.8±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 15±3A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature High temperature discharge protection 70±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L127.5*W16*T4 mm NTC: / Temperature switch: 70 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S Model: PCM-L04S150-F59(4S) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 150A Maximal continuous discharging current 150A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.07V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.00±0.1V Current protection(Battery pack) Discharge Over current detection current 400±50A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L255 *W115 *T15 mm NTC: / Temperature switch:65℃/90℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S Model: PCM-LX16S35A-AY215(LI-16S50A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:67.2V CC/CV(4.2v/Cell)16s Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 50A Maximal continuous discharging current 50A Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.1±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±30A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L100*W58*T13 mm NTC: / Temperature switch:65℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L10S10-C19(LI-10S10A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C ,Bluetooth Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V ±0.05V Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L100*W50*T10mm NTC:10KNTC B=3435 Temperature switch:/℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Protection Circuit Module Specifications For 37V Li-ion/Li-Po Battery Pack Model: PCM-L10S10-C19 (LI-10S) No. Test item(Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface HDQ or I2C 2 Capacity Designing battery capacity 8500mAh Designing battery capacity 8500mAh Max capacity(Battery pack) 320000mAh Min capacity(Battery pack) 800mAh External capacity Indication Gas gauge algorithm Impedance Track 3 Voltage Charging voltage DC: 37V CC/CV(4.2V/1cell) Balance voltage for single cell 4.2±0.05V 4 Current Balance current for single cell 68±10mA Normal operating-mode current:Gas Gauge in NORMAL mode, ILOAD > Sleep Current 160 uA SLEEP operating-mode current:Gas Gauge in SLEEP mode, ILOAD < Sleep Current 80 uA FULL SLEEP operating-mode current:Gas Gauge in FULL SLEEP mode, ILOAD < Sleep Current 25 uA Maximal continuous charging current 10A Maximal continuous discharging current 10A 5 Over charge Protection Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V 6 Over discharge protection Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 10—30mS Over discharge release voltage 3.0±0.1V 7 Over current protection Over current detection current 40±5A Detection delay time 5ms—60ms Release condition Cut load 8 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release …
www.ayaatech.com
PCM for 10S-16S PCM-L12S25-513(10S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 36V CC/CV(3.6V/cell) DC 42V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 14A 14A Max. cont. discharging current 14A 14A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L80*W60*T20mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.08±0.05V …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S05-K31 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:6.9V~8.4V CC/CV(3.45V~4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 2-5A Maximal continuous discharging current 2-5A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 5-12A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L48*W7*T3mm NTC:10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB35S170A-AY162(LI-35S170A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 147V CC/CV(4.2v/Cell)35S Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 170A Maximal continuous discharging current 170A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 600±100A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L174*W157*T13 mm NTC: / Temperature switch: 75℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
Smart Battery Managment with Fuel Guage Model: PCM-L10S30-C50(LI-10S30A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface I2C,Bluetooth Voltage Charging voltage DC:42V CC/CV(4.2v/Cell)10S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L140*W50*T10mm NTC:10KNTC B=3435 Temperature switch:70℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:AY-L5S100A-M069 No. Test item (Testatnormal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&CANBUS&UART 2 Voltage Charging voltage DC:17.25V~21V CC/CV(3.45V~4.2V/Cell)5s 3 Supply Current Normal operating-mode current (Gas Gauge IC) ≤25mA(average) SLEEP operating-mode current (Gas Gauge IC) ≤150uA(average) Maximal continuous charging current 30-100A Maximal continuous discharging current 30-100A Balance current for single cell 36-42mA 4 Over charge Protection (single cell) Balance voltage for single cell 3.6-4.2V Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over charge current protection 40-120A Detection delay time 1S Over current detection current 1 80-240A Detection delay time 2-5S Over current detection current 2 90-300A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L180 *W75 *T20 mm NTC: 10K NTC*2pcs Temperature switch:/ Weak current switch:YES Activation Method: /
www.ayaatech.com
BMS/PCM with Communications Model:AY-L4S100A-M074 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface RS485&UART&Bluetooth 2 The BMS supports max 8S battery packs, there are 4 battery packs in series for 4S ,and 2 battery packs in series for 8S, all support infinite parallels connection. 3 current in parallel ≤10A 4 Voltage Charging voltage DC:13.8V~33.6V CC/CV(3.45V~4.2V/Cell)4/8s 5 Supply Current Normal operating-mode current (Gas Gauge IC) ≤30mA(average) SLEEP operating-mode current (Gas Gauge IC) ≤200uA(average) Maximal continuous charging current 100-200A Maximal continuous discharging current 100-200A Balance current for single cell 36-42mA 6 Over charge Protection (single cell) Balance voltage for single cell 3.6-4.2V Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 7 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 8 Over current protection(Battery pack) Over charge current protection 110-210A Detection delay time 1S Over current detection current 1 200-400A Detection delay time 2-5S Over current detection current 2 300-600A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 9 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S10-K32 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:6.9V~8.4V CC/CV(3.45V~4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 3-10A Maximal continuous discharging current 3-10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 5-25A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L52*W9*T3mm NTC:10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S30-J56 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:6.9V~8.4V CC/CV(3.45V~4.2V/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 5-30A Maximal continuous discharging current 5-30A Balance current for single cell 36-42mA Over-charge Protection (single cell) Balance voltage for single cell 3.6-4.20V Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 15-90A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W35*T3mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S Protection Circuit Module Specifications For 37V Li-ion Battery Pack PCM-L10S20-E23(10S) No. Test item Criterion 1 Voltage Charging voltage DC: 42V CC/CV Balance voltage for single cell 4.20±0.05V 2 Current Balance current for single cell 68±10mA Current consumption ≤150μA Maximal continuous charging current 25A Maximal continuous Discharging current 25A 3 Over charge Protection Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V 4 Over discharge protection Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—400mS Over discharge release voltage 3.0±0.1V 5 Over current protection Over current detection current 55±10A Detection delay time 100ms—300ms Release condition charger release 6 Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load 7 Resistance Protection circuitry(MOSFET) ≤20mΩ 8 Temperature Operating Temperature Range -40~+70℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
BMS/PCM with Communications Model: PCM-L12S10-E13(LI-12S10A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBus,Bluetooth Voltage Charging voltage DC:50.4V CC/CV(4.2v/Cell)12S Capacity Designing battery capacity(PCM) 320Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤400uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage Optional Over charge detection delay time 0.5—2S Over charge release voltage Optional Over discharge protection(single cell) Over discharge detection voltage Optional Over discharge detection delay time 0.5—2S Over discharge release voltage Optional Current protection(Battery pack) Discharge Over current detection current Adjustable Detection delay time 100—800mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE:L160*W128*T15mm NTC:10KNTC B=3435 Temperature switch:/℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L06S20-H22 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 5-20A Maximal continuous discharging current 5-20A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 15-60A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L103*W55.6*T6mm NTC: 10K NTC*2PCS Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-LI01S6-264(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L15*W3.7*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) 4.10±0.05V 4.05±0.05V …
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L06S20-H22 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Voltage Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 5-20A Maximal continuous discharging current 5-20A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 15-60A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L103*W55.6*T6mm NTC: 10K NTC*2PCS Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L04S100-F49 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface I2C 2 Voltage Charging voltage DC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 30-100A Maximal continuous discharging current 30-100A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 90-300A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L200*W115*T14 mm NTC: 10K NTC Temperature switch:65℃/90℃ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S Model: PCM-L13S30-B73 (13S) No. Test Item Criterion 1 Voltage Charging voltage DC: 54.6V CC/CV Balance voltage for single cell 4.20±0.05V 2 Current Balance current for single cell 42±5mA Current consumption for single cell ≤20μA Maximal continuous charging current 5A Maximal continuous Discharging current 30A 3 Over charge protection Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V 4 Over discharge protection Over discharge detection voltage 2.50±0.1V Over discharge detection delay time 0.2S—1S Over discharge release voltage 2.50±0.1V 5 Over current protection Over current detection current 100±20A Detection delay time 5ms—60ms Release condition Cut load, Auto Recovery 6 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load, Auto Recovery 7 Resistance Protection circuitry ≤20mΩ 8 Temperature Operating Temperature Range -40~+70℃ Storage Temperature Range -40~+125℃
www.ayaatech.com
BMS/PCM with Communications Model:PCM-L06S50-L33 No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface I2C 2 Voltage Charging voltage DC:20.7V~25.2V CC/CV(3.45V~4.2V/Cell)6s Cell-balance detection voltage(Charge balance) can be adjusted by required Cell-balance detection delay time 0.5S—2S 3 Current Normal operating-mode current (Gas Gauge IC) 600 uA(average) SLEEP operating-mode current (Gas Gauge IC) 350 uA(average) Maximal continuous charging current 10-50A Maximal continuous discharging current 10-50A 4 Over charge Protection (single cell) Over charge detection voltage 3.6-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 3.4-4.15V 5 Over discharge protection (single cell) Over discharge detection voltage 2.0-3.0V Over discharge detection delay time 150—300mS Over discharge release voltage 2.3-3.2V 6 Over current protection(Battery pack) Over current detection current 30-150A Detection delay time 50ms—300ms Release condition Cut load,Auto Recovery 7 Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load,Auto Recovery 8 Resistance Protection circuitry (MOSFET) ≤50mΩ 9 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L105*W65 *T8mm NTC:10K NTC*2PCS Temperature switch: / Weak current switch:/ Activation Method: /
www.ayaatech.com
PCM for 17S-35S Model: PCM-LB35S320A-AY353(LI-35S350A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 147V CC/CV(4.2v/Cell)35S Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 350A Maximal continuous discharging current 350A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.50±0.08V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 1500±500A Detection delay time 1000mS-2000mS Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature Operating Temperature Range -40~+60℃ Storage Temperature Range -40~+85℃ SIZE: L279*W200*T38 mm NTC: / Temperature switch: / Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-L17S70-F95(LI-ION-17S70A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:71.2V CC/CV(4.2V/Cell)17S Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 40A Maximal continuous discharging current 40A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 1—3S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±30A Detection delay time 50-350mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W80*T21mm NTC: / Temperature switch: 60℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-L24S40-598(Li-24S40A) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:100.8V CC/CV(4.2V/Cell)24S Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 40A Maximal continuous discharging current 40A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.50±0.05V Over discharge detection delay time 1—3S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 120±30A Detection delay time 50-350mS Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L115*W75*T25 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 17S-35S Model: PCM-L25S60-G31 (LI-25S60A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:105V CC/CV(4.2v/Cell)25s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 60A Maximal continuous discharging current 60A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.75±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 200±30A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -20~+85℃ Storage Temperature Range -40~+125℃ SIZE :L160*W110*T15mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S RV-LF4S1P-10A(A-1)(4S) No Test item Criterion 1 Charging voltage DC:14.4V CC/CV Voltage Balance voltage for single cell 3.60V±0.025V 2 Balance current for single cell 120±10mA Current consumption for single cell ≤20μA Current Maximal continuous charging current 10A Maximal continuous Discharging current 10A 3 Over charge protection(single cell) Over charge detection voltage 3.90±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 3.8±0.025V 4 Over discharge protection(single cell) Over discharge detection voltage 2.0±0.062V Over discharge detection delay time 10—300mS Over discharge release voltage 2.0±0.062V 5 Over current protection Over current detection current 15±5A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery 6 Short protection Detection condition Exterior short circuit Detection delay time 200-500us Release condition Cut load, Auto Recovery 7 Resistance Protection circuitry ≤20mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L150*W20
www.ayaatech.com
PCM for 3S-4S PCM-Li6530-037(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 10A 10A Max. cont. discharging current 10A 10A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W30mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 5S-9S PCM-Li05S8-002(B)(5S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 18VCC/CV(3.6V/cell) DC 21V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L80*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 1S-2S PCM-2918-869 (1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 3A 3A Max. cont. discharging current 3A 3A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension Diameter=17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V …
www.ayaatech.com
PCM for 3S-4S Model: PCM-Li4S5-068 (LI-4S4A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:50.4V CC/CV(4.2v/Cell)12s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤20uA Maximal continuous charging current 4A Maximal continuous discharging current 4A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.7±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 10±3A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature charge protection / Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L26 *W26 *T3 mm NTC: / Temperature switch: / Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S PCM-L16S30-922(16S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 57.6V CC/CV(3.6V/cell) DC:67.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±10mA 42±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 30A 30A Max. cont. discharging current 30A 30A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L120*65*T10mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release …
www.ayaatech.com
PCM for 1S-2S PCM-L02S06-879(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC 8.4V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 1S-2S PCM-L01S05-792(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L28*W10*T1.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 10S-16S PCM-L16S15-582(16S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 57.6V CC/CV(3.6V/cell) DC:67.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 72±10mA 84±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L128*50*T12mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release …
www.ayaatech.com
PCM for 1S-2S PCM-Li02S3-129(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L51*W9*T2mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 3S-4S PCM-Li04S7-256(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC 16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 5S-9S PCM-L06S12-520(6S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 21.6VCC/CV(3.6V/cell) DC 25.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 12A 12A Max. cont. discharging current 12A 12A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L64*W50*T4.6mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 1S-2S Model: PCM-L02S30-A89(LI-2S30A) Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:8.4V CC/CV(4.2v/Cell)2s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 30A Maximal continuous discharging current 30A Balance current for single cell 42±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 100±20A Detection delay time 5ms—60ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W35*T6.5 mm NTC: / Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S PCM-L06S10-554(6S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 21.6V CC/CV(3.6V/cell) DC:25.2V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 8A 8A Max. cont. discharging current 8A 8A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L65*W36*T5.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 1S-2S PCM-Li02S5-027(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33.5*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-216(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L29.5*W6.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 1S-2S PCM-Li02S3-076(2S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC:7.2V CC/CV(3.6V/cell) DC:8.4V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L33*W14.7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 1S-2S PCM-Li01S8-015(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 5A 5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L32*W5*T2.0mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 10S-16S PCM-L10S20-858(A-1)(10S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 36V CC/CV(3.6V/cell) DC 42V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 5A 5A Max. cont. discharging current 20A 20A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L63*W30*T17mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge …
www.ayaatech.com
PCM for 5S-9S PCM-LB8S15A-AY026(8S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 28.8VCC/CV(3.6V/cell) DC:33.6V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 15A 15A Max. cont. discharging current 15A 15A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L65*W40*T8mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release voltage(V) …
www.ayaatech.com
PCM for 1S-2S PCM-LB2S15A-AY329 (LI-2S15A) Model: PCM-LB2S15A-AY329 (LI-2S15A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV(4.2V/Cell)2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 15A Maximal continuous discharging current 15A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection (Battery pack) Discharge Over current detection current 40±10A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤60mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L55*W20*T2.8 mm NTC: / Temperature switch:/ Weak current switch:/ special requirement: /
www.ayaatech.com
PCM for 10S-16S Model: PCM-L16S200-H69(LI-16S200A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:57.6V CC/CV(3.6V/Cell)16S Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 200A Maximal continuous discharging current 200A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.20V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.05V Over discharge detection delay time 1—3S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 450±50A Detection delay time 50-350mS Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L300*W140*T15 mm NTC: / Temperature switch: 60℃ (the batteries temperature) Weak current switch:/ Activation Method:/ B+=P+=Charge+ CH-=Charge- P-=Discharge-
www.ayaatech.com
PCM for 3S-4S PCM-Li04S8-026(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L100*W16*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 3S-4S PCM-LB4S10A-AY151(LI-3S9A) Model: PCM-LB4S10A-AY151(LI-3S9A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:12.6V CC/CV(4.2v/Cell)3s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤10uA Maximal continuous charging current 9A Maximal continuous discharging current 9A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.08V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 30±5A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤50mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W30*T4 mm NTC: Yes 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 5S-9S Model: PCM-L08S25-A72(LF-8S10A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 28.8V CC/CV(3.6V/Cell)8S Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 25A Maximal continuous discharging current 25A Balance current for single cell 36mA±5mA Over-charge Protection(single cell) Balance voltage for single cell 3.6V±0.05V Over charge detection voltage 3.90±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.80±0.10V Over discharge protection(single cell) Over discharge detection voltage 2.00±0.10V Over discharge detection delay time 0.5S—2S Over discharge release voltage 2.30±0.10V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 60±10A Detection delay time 200-600us Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L119*W51*T6.5mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 3S-4S PCM-L04S12-406(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell 3.6V±0.05V 4.20V±0.025V 2 Current Balance current for single cell 36mA±2mA 84mA±10mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 12A 12A Max. cont. discharging current 12A 12A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L70*W40*T3mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 10S-16S PCM-LX10S20A-AY047(10S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 36V CC/CV(3.6V/cell) DC:42V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 42±5mA Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 20A 20A Max. cont. discharging current 20A 20A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W54.5*T7mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 5S-9S Model: PCM-L07S12-476V3(LI-7S12A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:29.4V CC/CV(4.2v/Cell)7s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 12A Maximal continuous discharging current 12A Balance current for single cell 42±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.18±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 35±5A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L123*W34*T5 mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 1S-2S PCM-Li01S3-078(1S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 3.6V CC/CV(3.6V/cell) DC:4.2V CC/CV(4.2V/cell) Balance voltage for single cell …… …… 2 Current Balance current for single cell …… …… Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 2.5A 2.5A Max. cont. discharging current 2.5A 2.5A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.805±0.05V 4.05 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L30*W5.5*T2.5mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over …
www.ayaatech.com
PCM for 3S-4S PCM-L04S10-178(4S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 14.4V CC/CV(3.6V/cell) DC:16.8V CC/CV(4.2V/cell) Balance voltage for single cell / / 2 Current Balance current for single cell / / Current consumption for single cell ≤20μA ≤20μA Max. continuous charging current 7A 7A Max. cont. discharging current 7A 7A 3 Over charge protection(single cell) Over charge detection voltage 3.90V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.80±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L60*W28mm Optional Parameters: Over charge detection voltage (V) 4.28±0.025V 4.25±0.025V 3.65±0.025V Over charge release …
www.ayaatech.com
PCM for 3S-4S Model:PCM-L04S07-B28 Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:13.8V~16.8V CC/CV(3.45V~4.2V/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 4-7A Maximal continuous discharging current 4-7A Over-charge Protection (single cell) Over charge detection voltage 3.65-4.35V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05-4.15V Over discharge protection(single cell) Over discharge detection voltage 2.4-3.0V Over discharge detection delay time 10—200mS Over discharge release voltage 2.5-3.2V Current protection(Battery pack) Discharge Over current detection current 12-21A Detection delay time 5ms—20ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L70*W17*T3mm NTC: 10K NTC Temperature switch:/ Weak current switch:/ Activation Method:/
www.ayaatech.com
PCM for 10S-16S PCM-L15S30-960(13S) No Test item Criterion Lifepo4 Li-ion/Li-polymer 1 Voltage Charging voltage DC 46.8V CC/CV(3.6V/cell) DC:54.6V CC/CV(4.2V/cell) Balance voltage for single cell 3.60±0.025V 4.20±0.025V 2 Current Balance current for single cell 36±5mA 67±5mA Current consumption for single cell ≤100μA ≤100μA Max. continuous charging current 5A 5A Max. cont. discharging current 30A 30A 3 Over charge protection(single cell) Over charge detection voltage 3.65V±0.025V(optional) 4.25±0.025V(optional) Over charge detection delay time 0.5-2.0S 0.5S—2.0S Over charge release voltage 3.65±0.05V 4.15 ±0.05V 4 Over discharge protection(single cell) Over discharge detection voltage 2.00±0.8V(optional) 2.5±0.08V(optional) Over discharge detection delay time 10-300mS 10-300mS Over discharge release voltage 2.3±0.1V 3.0±0.1V 5 Over current protection Over current detection voltage depend on the above points depend on the above points Over current detection current final data fixed from actual test final data fixed from actual test Detection delay time 5-20ms 5-20ms Release condition Cut load,Auto release Cut load,Auto release 6 Short protection Detection condition Exterior short circuit Detection delay time 100~500us Release condition charge up 7 Resistance Protection circuitry ≤50mΩ 8 Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ 9 Dimension L65*50*T18.5mm Optional Parameters: Over charge detection voltage (V) 3.65±0.025V 4.25±0.025V 4.28±0.025V Over charge release …
Battery Series | Model | Picture | Working Current | Balance | Size | Remark |
---|---|---|---|---|---|---|
1S | PCM-LX01S06A-AY18650B | 8A | No | L18*W18*T2 mm | With Fuse | |
1S | PCM-L01S05-792 | 5A | No | L28*W10*T2 mm | N/A | |
1S | PCM-Li01S2A-2538 | 2A | NO | L25*W3.8*T2.0mm | ||
1S | PCM-L01S03-107 | 2.5A | No | L13.7*W13.57*T2.0mm | With NTC | |
1S | PCM-L01S02-L41 | 5A | NO | ∮25*T3mm | with NTC | |
1S | PCM-L01S3-136 | 3A | No | D18*T2 mm | N/A | |
1S | PCM-Li01S3-216 | 2.5A | No | L29.5*W6.5*T2.5mm | With NTC | |
1S | PCM-Li01S8-015 | 5A | No | L32*W5*T2.0mm | With NTC | |
1S | PCM-L01S05-H92 | 5A | NO | L48*W5*T3mm | with NTC | |
1S | PCM-Li01S3-078 | 2.5A | No | L30*W5.5*T2.5mm | With NTC | |
1S | PCM-L01S08-444 | 8A | No | L36*W7.5*T2 mm | With NTC | |
1S | PCM-G01S05-932 | 5A | No | L55*W17*T2.5 mm | With I2C | |
1S | PCM-LX01S3A-AY245 | 3A | No | L18*W18*T2mm | With NTC | |
1S | PCM-L01S03-L07 | 3A | NO | ∮14*T3mm | N/A | |
1S | PCM-LI01S6-264 | 5A | No | L15*W3.7*T2.5mm | N/A | |
1S | PCM-2918-869 (1S) | 3A | D17*T2 mm | D17*T2 mm | N/A | |
1S | PCM-L01S05-792(1S) | 5A | NO | L28*W10*T2 mm | N/A | |
1S | PCM-Li01S3-216(1S) | 2.5A | NO | L29.5*W6.5*T2.5mm | N/A | |
1S | PCM-Li01S8-015(1S) | 5A | NO | L32*W5*T2.0mm | N/A | |
1S | PCM-Li01S3-078(1S) | 2.5A | NO | L30*W5.5*T2.5mm | N/A | |
2S | PCM-L02S30-A89 | 30A | Yes | L120*W35*T6.5 mm | N/A | |
2S | PCM-Li02S5-027 | 5A | No | L33.5*W16*T3mm | N/A | |
2S | PCM-Li02S3-076 | 2.5A | No | L33*W14.7*T2 mm | N/A | |
2S | PCM-L02S05-D79 | 10A | No | L54*W12 mm | With NTC,I2C | |
2S | PCM-L02S06-336 | 8A | Yes | L40*W18*T3mm | N/A | |
2S | PCM-L02S10-166 | 10A | No | L51*W9*T2.5 mm | N/A | |
2S | PCM-LB2S15A-AY329 | 15A | No | L55*W20*T2.8 mm | N/A | |
2S | PCM-L02S15-K67 | 15A | NO | L60*W28*T4mm | with NTC | |
2S | PCM-Li2S5A-2807 | 5A | No | L28*W7*T2mm | N/A | |
2S | PCM-LB2S15A-AY037 | 15A | No | L90*W14*T3mm | With NTC | |
2S | PCM-LX2S2A-AY321 | 2A | No | L34*W17*T3 mm | N/A | |
2S | PCM-L02S06-H91 | 10A | NO | L55*W7.45*T3mm | with NTC | |
2S | CV243 | 5A | YES | L50*W14*T2.6mm | HDQ or I2C | |
2S | PCM-L02S20-265V1 | 20A | No | L120*W37*T4mm | N/A | |
2S | PCM-L02S10-881 | 5A | No | L34.5*W34.5mm | N/A | |
2S | PCM-Li2S3A-4408 | 3A | No | L44*W8*T2mm | N/A | |
2S | PCM-L02S05-K31 | 5A | NO | L48*W7*T3mm | with NTC | |
2S | PCM-L02S10-K32 | 10A | NO | L52*W9*T3mm | with NTC | |
2S | PCM-L02S30-J56 | 30A | NO | L120*W35*T3mm | N/A | |
2S | PCM-L02S06-879(2S) | 5A | NO | L34.5*W16mm | with Temperature Switch | |
2S | PCM-Li02S3-129(2S) | 5A | NO | L40*W7*T2.5 mm | N/A | |
2S | PCM-L02S30-A89 | 30A | NO | L120*W35*T6.5 mm | N/A | |
2S | PCM-Li02S5-027(2S) | 5A | NO | L33.5*W16*T3mm | N/A | |
2S | PCM-Li02S3-076(2S) | 2.5A | NO | L33*W14.7*T2 mm | N/A | |
2S | PCM-LB2S15A-AY329 | 15A | NO | L55*W20*T2.8 mm | N/A | |
3S | PCM-L03C03-D13 | 3A | No | L18*W18*T3.8 mm | N/A | |
3S | PCM-L03C03-D13 | 3A | NO | L18*W18*T4mm | N/A | |
3S | PCM-L03S04-730 | 4A | No | L32*W32*T3.5 mm | N/A | |
3S | PCM-L03S07-B29 | 7A | NO | L51.5*W16*T3mm | N/A | |
3S | AY-LX3S1.5A-T002 | 2A | No | L127.5*W16*T4 mm | Temperature Switch,NTC,I2C | |
3S | PCM-LB4S10A-AY151 | 9A | NO | L60*W30*T4 mm | N/A | |
4S | RV-LF4S1P-10A | 10A | Yes | L150*W20 mm | with Temperature Switch | |
4S | PCM-L04S35-E22 | 20A | Yes | L78*W52*T5 mm | Temperature Switch,SMBUS,Bluetooth | |
4S | PCM-LX4S10A-AY102 | 10A | No | L50*W16*T4 mm | With NTC | |
4S | PCM-LB04S30-1506 | 30A | Yes | L65*W65*T4mm | with Temperature Switch | |
4S | PCM-Li04S8-068 | 4A | No | L26*W26*T3mm | N/A | |
4S | PCM-L04S15-E95 | 12A | Yes | L60*W26*T4mm | With NTC | |
4S | PCM-L04S04-L31 | 4A | Yes | L60*W55*T9.5mm | with SMBus,NTC | |
4S | PCM-Li6530-037 | 10A | No | L60*W30mm | N/A | |
4S | PCM-L05S06-338 | 7A | Yes | L70*W33*T3MM | N/A | |
4S | PCM-LX4S5A-AY186 | 7A | No | L65*W48*T5 mm | With NTC | |
4S | PCM-L04S30-1516 | 30A | Yes | L60*W50*T5 mm | with Temperature Switch | |
4S | PCM-L04S30-G28+PCM-IICUART-E99 | 30A | Yes | L80*W60*T8 mm | With NTC,SMBUS,RS485,RS232 | |
4S | PCM-Li04S4-011 | 4A | No | L50*W16*T3 mm | with NTC | |
4S | PCM-Li04S7-256 | 7A | Yes | L50*W21*T3 mm | N/A | |
4S | PCM-Li04S8-016 | 7A | No | L50*W16*T3 mm | N/A | |
4S | PCM-L04S10-187 | 12A | Yes | L90*W40*T5 mm | N/A | |
4S | PCM-L04S07-427 | 7A | No | L100*W60*T4 mm | With NTC | |
4S | PCM-LB16S100A-AY351 | 80A | Yes | L149*W80*T14mm | with Temperature Switch | |
4S | PCM-L04S100-G09 | 100A | Yes | L250*W120*T18mm | With SMBUS,Heating function | |
4S | PCM-Li04S8-026 | 7A | No | L100*W16*T3mm | N/A | |
4S | AY-LB4S12A-T005 | 12A | Yes | L60*W35*T7 mm | With NTC | |
4S | PCM-L04S10-178 | 10A | No | L60*W28*T3 mm | N/A | |
4S | PCM-L04S16-761 | 20A | Yes | ∮52*T5mm | N/A | |
4S | PCM-L03S06-337 | 7A | Yes | L61*W25*T2.6mm | N/A | |
4S | PCM-L04S12-144 | 12A | No | L40*W40*T3.5 mm | N/A | |
4S | PCM-LB4S50A-AY196 | 50A | Yes | L136*W32*T5 mm | with Temperature Switch | |
4S | PCM-LB4S80A-AY143 | 80A | Yes | L135*W95*T8.5 mm | with Temperature Switch | |
4S | PCM-LB20S400A-AY306 | 300A | Yes | L175 *W116.5*T18 mm | with Temperature Switch | |
4S | PCM-L04S150-F59 | 150A | Yes | L255*W115*T15 mm | Temperature Switch | |
4S | AY-L4S100A-M074 | 200A | Yes | L180*W93*T18mm | unlimited parale connections,with RS485,UART,Bluetooth | |
4S | PCM-L04S100-F49 | 100A | Yes | L200*W115*T14mm | with I2C, NTC,Temperature Switch | |
4S | RV-LF4S1P-10A(A-1)(4S) | 10A | YES | L150*W20 mm | With Temperature Switch | |
4S | PCM-Li6530-037(4S) | 10A | NO | L60*W30mm | N/A | |
4S | PCM-Li04S8-068(4S) | 4A | NO | L26*W26*T3mm | N/A | |
4S | PCM-Li04S7-256 (4S) | 7A | YES | L50*W21*T3 mm | with Temperature Switch | |
4S | PCM-Li04S8-026(4S) | 7A | NO | L100*W16*T3mm | N/A | |
4S | PCM-L04S12-406(4S) | 12A | YES | L70*W40*T3 mm | N/A | |
4S | PCM-L04S10-178(4S) | 7A | NO | L60*W28*T3 mm | N/A | |
4S | PCM-L04S07-B28 | 7A | NO | L70*W17*T3mm | N/A | |
5S | PCM-L05S75-J49 | 75A | Yes | L130*W116*T8mm | with SMBus,NTC | |
5S | PCM-Li05S8-002(B) | 7A | No | L80*W16*T3 mm | N/A | |
5S | PCM-L05S60-F91 | 60A | Yes | L120*W65*T11 mm | with Temperature Switch | |
5S | PCM-LX5S7A-AY041 | 7A | No | L82*W16*T3 mm | N/A | |
5S | PCM-L05S06-338 | 7A | Yes | L70*W33*T3 mm | N/A | |
5S | PCM-LX5S20A-AY043 | 20A | Yes | L90*W42*T9 mm | N/A | |
5S | AY-L5S20A-M057 | 20A | Yes | L80*W60*T20mm | with RS485,CANBUS | |
5S | AY-L5S100A-M069 | 100A | Yes | L180*W75*T20mm | with RS485,CANBUS,UART | |
5S | PCM-Li05S8-002(B)(5S) | 7A | NO | L80*W16*T3 mm | N/A | |
6S | PCM-L06S10-554 | 10A | Yes | L64*W36*T5 mm | With NTC | |
6S | PCM-L06S10-J15 | 10A | No | L109*W17*T5mm | with SMBus,NTC | |
6S | PCM-L06S12-520 | 12A | Yes | L64*W50*T4.6 mm | N/A | |
6S | AY-LX6S15A-T016 | 15A | No | L52*W34*T6 mm | With NTC | |
6S | PCM-L06S07-849 | 7A | Yes | L51*W26*T4 mm | N/A | |
6S | PCM-L06S20-H22 | 20A | Yes | L103*W55.6*T6mm | with SMBus,NTC | |
6S | PCM-L06S20-H22 | 20A | Yes | L103*W55.6*T6mm | with SMBus,NTC | |
6S | PCM-L06S50-L33 | 50A | Yes | L105*W65*T8mm | with I2C, NTC | |
6S | PCM-L06S12-520 | 12A | YES | L64*W50*T4.6 mm | With Temperature Switch | |
6S | PCM-L06S10-554(6S) | 8A | YES | L64*W36*T5 mm | with Temperature Switch | |
7S | PCM-L07S15-K39 | 15A | Yes | L120*W63*T8mm | with SMBus,NTC | |
7S | PCM-L07S10-811 | 10A | Yes | L60*W60*T17 mm | N/A | |
7S | PCM-L08S08-953 | 5A | YES | L100*W45*T6mm | With 10K NTC | |
7S | AY-LB7S10A-T004 | 10A | Yes | L100*W65*T8 mm | With NTC | |
7S | PCM-L07S08-747 | 8A | Yes | L64*W41*T5 mm | With NTC | |
7S | PCM-L07S12-476V3 | 12A | NO | L123*W34*T5 mm | N/A | |
8S | PCM-LB24S100A-AY233 | 80A | No | L90*W65*T10 mm | with Temperature Switch | |
8S | PCM-LB8S15A-AY026 | 15A | Yes | L65*W40*T8 mm | with Temperature Switch | |
8S | PCM-L08S08-953 | 8A | Yes | L100*W45*T6 mm | With NTC,I2C | |
8S | PCM-L08S08-331 | 8A | Yes | L72.5*W65*T3 mm | with Temperature Switch | |
8S | AY-LB8S5A-T003 | 8A | Yes | L60.3*W40*T7 mm | N/A | |
8S | PCM-L08S60-K38 | 60A | Yes | L136*W80*T11mm | with I2C&Bluetooth,Temperature Swtich,NTC | |
8S | PCM-LB8S15A-AY026(8S) | 15A | YES | L65*W40*T8 mm | with Temperature Switch | |
8S | PCM-L08S25-A72 | 25A | NO | L119*W51*T6.5 mm | N/A | |
10S | PCM-L10S60-C05 | 60A | No | L110*W91.5*T10mm | With I2C,Bluetooth | |
10S | PCM-L10S25-B66 | 15A | Yes | L70*W36*T19 mm | With Temperature Switch | |
10S | PCM-L10S20-858 | 20A | Yes | L63*30*T17 mm | with Temperature Switch | |
10S | PCM-LX10S20A-AY047 | 20A | Yes | L60*W54.5*T7 mm | With NTC | |
10S | AY-LB10S19A-T006 | 20A | Yes | L90*W35*T7.5 mm | With NTC,SMBUS | |
10S | PCM-L10S15-A28 | 15A | Yes | L140*W26*T7.5 mm | With Temperature Switch | |
10S | PCM-L10S20-E67 | 20A | Yes | L178*W62*T10mm | With I2C,Bluetooth | |
10S | AY-L10S15A-M051 | 20A | Yes | L85*W55*T20mm | with RS485,CANBUS | |
10S | PCM-L10S10-B70 | 20A | Yes | L68*W49*T11mm | Temperature Switch | |
10S | PCM-L10S10-914 | 10A | Yes | L90*W50*T10mm | With I2C,Bluetooth | |
10S | PCM-LB10S15-288V1 | 15A | Yes | L70*W60*T11 mm | With NTC | |
10S | PCM-L10S30-A32 | 30A | Yes | L90*W70*T16mm | With I2C | |
10S | PCM-L10S10-C19 | 10A | Yes | L100*W50*T10mm | With I2C,Bluetooth | |
10S | PCM-L10S10-C19 | 10A | Yes | L105*W50*T8 mm | With NTC | |
10S | PCM-L10S30-C50 | 30A | No | L140*W50*T10mm | With I2C,Bluetooth | |
10S | PCM-L10S30-E23 | 25A | Yes | L92*W54*T9 mm | Temperature Switch | |
10S | PCM-L10S20-858(A-1) | 20A | YES | L63*30*T17 mm | with Temperature Switch | |
10S | PCM-LX10S20A-AY047 | 20A | YES | L60*W54.5*T7 mm | with Temperature Switch | |
12S | PCM-L12S25-513 | 25A | Yes | L80*60*T20 mm | Temperature Switch | |
12S | PCM-L12S10-E13 | 10A | No | L160*W128*T15mm | With SMBus,Bluetooth | |
13S | PCM-L13S50-911 | 40A | YES | L100*W60*T20 mm | With Temperature Switch | |
13S | PCM-L13S30-B73 | 30A | Yes | Yes | Temperature Switch | |
14S | PCM-LX14S15A-AY200 | 15A | No | L257*W71*T6.5 mm | N/A | |
14S | PCM-L14S40-K77 | 50A | Yes | L160*W65*T12mm | with SMBus,NTC | |
14S | PCM-L14S200-J51 | 200A | Yes | L225*W140*T14.5mm | with SMBus&Bluetooth,Electronic Switch | |
15S | PCM-L15S30-960 | 30A | YES | L65*50*T18.5 mm | with Temperature Switch | |
16S | PCM-L16S100-F83 | 100A | Yes | L240*W120*T15 mm | Temperature Switch | |
16S | PCM-L16S15-582 | 15A | Yes | L128*50*T12 mm | with Temperature Switch | |
16S | PCM-L16S30-A44V4 | 30A | Yes | L120*W65*T8 mm | Temperature Switch | |
16S | PCM-L16S30-922 | 30A | Yes | L120*65*T10 mm | with Temperature Switch | |
16S | PCM-L16S100-H87 | 100A | Yes | L220*W100*T21 mm | With Temperature Switch,NTC,I2C,Bluetooth | |
16S | PCM-L16S200-F77 | 200A | Yes | L255*W115*T15mm | With HDQ,I2C,BlueTooth | |
16S | PCM-L16S50-F34 | 50A | Yes | L250*W135*T10mm | With HDQ,I2C,Bluetooth | |
16S | PCM-LB16S30A-AY087-LB16S30A | 30A | Yes | L105*W65*T10 mm | With Temperature Switch | |
16s | PCM-LB16S120-AY279 | 100A | YES | L125*W62*T25mm | SMBUS or CANBUS or RS485 | |
16S | PCM-L16S25-591 | 20A | Yes | L78*W55*T18mm | N/A | |
16S | PCM-LX16S35A-AY215 | 50A | Yes | L100*W58*T13 mm | Temperature Switch | |
16S | PCM-L16S30-922(16S) | 30A | YES | L120*65*T10 mm | with Temperature Switch | |
16S | PCM-L16S15-582(16S) | 15A | YES | L128*50*T12 mm | with Temperature Switch | |
16S | PCM-L16S200-H69 | 200A | NO | L300*W140*T15 mm | N/A | |
17S | PCM-LB17S25A-AY068 | 25A | Yes | L120*W65*T13 mm | Temperature Switch | |
17S | PCM-L17S70-F95 | 70A | Yes | L120*W80*T21mm | With Temperature Switch | |
20S | PCM-LB20S400A-AY306 | 220A | Yes | L175*W116.5*T18 mm | Temperature Switch | |
20S | PCM-LB20S30A-AY024 | 40A | Yes | L120*W63*T10 mm | Temperature Switch | |
20S | PCM-LB20S170A-AY063 | 170A | Yes | L174*W157*T13 mm | Temperature Switch | |
20S | PCM-LB20S150A-AY065 | 150A | Yes | L200*W110*T19 mm | Temperature Switch | |
21S | PCM-LB21S40A-AY327 | 40A | Yes | L80*W60*T16 mm | With NTC | |
21S | PCM-LB21S100A-AY316 | 100A | Yes | L120*W65*T16 mm | Temperature Switch | |
24S | PCM-LB24S150A-AY072 | 150A | Yes | L125*W63*T15 mm | Temperature Switch | |
24S | PCM-L24S40-598 | 40A | Yes | L115*W75*T25mm | With Temperature Switch | |
25S | PCM-L25S60-G31 | 60A | Yes | L160*W110*T15mm | With Temperature Switch | |
35S | PCM-LB35S170A-AY162 | 170A | Yes | L174*W157*T13 mm | Temperature Switch | |
35S | PCM-LB35S320A-AY353 | 350A | Yes | L279*W200*T38 mm | N/A |