| No | Test item | Criterion | ||||
| Lifepo4 | Li-ion/Li-polymer | |||||
| 1 | Voltage | Charging voltage | DC 7.2V CC/CV(3.6V/cell) | DC:8.4V CC/CV(4.2V/cell) | ||
| Balance voltage for single cell | …… | …… | ||||
| 2 | Current | Balance current for single cell | …… | …… | ||
| Current consumption for single cell | ≤20μA | ≤20μA | ||||
| Max. continuous charging current | 5A | 5A | ||||
| Max. cont. discharging current | 5A | 5A | ||||
| 3 | Over charge protection(single cell) | Over charge detection voltage | 3.90V±0.025V(optional) | 4.25±0.025V(optional) | ||
| Over charge detection delay time | 0.5-2.0S | 0.5S—2.0S | ||||
| Over charge release voltage | 3.805±0.05V | 4.05 ±0.05V | ||||
| 4 | Over discharge protection(single cell) | Over discharge detection voltage | 2.00±0.8V(optional) | 2.5±0.08V(optional) | ||
| Over discharge detection delay time | 10-300mS | 10-300mS | ||||
| Over discharge release voltage | 2.3±0.1V | 3.0±0.1V | ||||
| 5 | Over current protection | Over current detection voltage | depend on the above points | depend on the above points | ||
| Over current detection current | final data fixed from actual test | final data fixed from actual test | ||||
| Detection delay time | 5-20ms | 5-20ms | ||||
| Release condition | Cut load,Auto release | Cut load,Auto release | ||||
| 6 | Short protection | Detection condition | Exterior short circuit | |||
| Detection delay time | 100~500us | |||||
| Release condition | charge up | |||||
| 7 | Resistance | Protection circuitry | ≤50mΩ | |||
| 8 | Temperature | Operating Temperature Range | -40~+85℃ | |||
| Storage Temperature Range | -40~+125℃ | |||||
| 9 | Dimension | L33.5*W16*T3mm | ||||
| Optional Parameters: | Over charge detection voltage (V) | 4.28±0.025V | 4.25±0.025V | 3.65±0.025V | ||
| Over charge release voltage(V) | 4.10±0.05V | 4.05±0.05V | 3.65±0.05V | |||
| Over discharge detection voltage | 3.00±0.8V | 2.80±0.8V | 2.50±0.8V | |||
| Over discharge release voltage(V) | 3.20±0.1V | 3.00±0.1V | 3.00±0.1V | |||