| Model: PCM-L02S10-166 (LI-2S10A) Ver: A | ||
| Test item (Test at normal temperature 25±2℃) | Criterion | |
| Voltage | Charging voltage | DC: 8.4V CC/CV(4.2V/Cell)2s |
| Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤10uA |
| Maximal continuous charging current | 10A | |
| Maximal continuous discharging current | 10A | |
| Over-charge Protection (single cell) | Over charge detection voltage | 4.25±0.05V |
| Over charge detection delay time | 0.5S—2S | |
| Over charge release voltage | 4.05±0.1V | |
| Over discharge protection (single cell) | Over discharge detection voltage | 2.4±0.05V |
| Over discharge detection delay time | 10—200mS | |
| Over discharge release voltage | 3.0±0.1V | |
| Current protection (Battery pack) | ChargeOver current detection current | / |
| Detection delay time | / | |
| Discharge Over current detection current | 20±5A | |
| Detection delay time | 5ms—50ms | |
| Release condition | Cut load, Auto Recovery | |
| Short protection | Detection condition | Exterior short circuit |
| Detection delay time | 200-600us | |
| Release condition | Cut load | |
| Resistance | Main loop electrify resistance | ≤65mΩ |
| Temperature | Operating Temperature Range | -40~+85℃ |
| Storage Temperature Range | -40~+125℃ | |
| SIZE: L51*W9*T2.5 mm | ||
| NTC: / Temperature switch: Weak current switch:/ Activation Method:/ | ||