BMS/PCM with Communications Model: PCM-L04S04-L31 Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface SMBUS Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Capacity Designing battery capacity(PCM) /Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤800uA Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current ≤350 uA Maximal continuous charging current 1A Maximal continuous discharging current 4A Balance current for single cell 56±10mA Over-charge Protection (single cell) Balance voltage for single cell 3.5±0.10V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) charge current protection 2±1A Detection delay time 0.5S—2S Discharge Over current protection1 12±1A Detection delay time 1S—3S Discharge Over current protection2 14±1A Detection delay time 0.5S—2S Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature discharge temperature protection -10~+65℃ charge temperature protection 0~+60℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L60*W55 *T9.5mm NTC:10K NTC Temperature switch: / ℃ (the batteries temperature) ... - AYAA TECHNOLOGY CO., LTD
Model: PCM-L04S04-L31 | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Communication Interface | SMBUS | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2v/Cell)4s |
Capacity | Designing battery capacity(PCM) | /Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤800uA |
Low-power operating mode current:Fuel gauge in SLEEP mode.ILOAD < Sleep Current | ≤350 uA | |
Maximal continuous charging current | 1A | |
Maximal continuous discharging current | 4A | |
Balance current for single cell | 56±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.5±0.10V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | charge current protection | 2±1A |
Detection delay time | 0.5S—2S | |
Discharge Over current protection1 | 12±1A | |
Detection delay time | 1S—3S | |
Discharge Over current protection2 | 14±1A | |
Detection delay time | 0.5S—2S | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 60mΩ |
Temperature | discharge temperature protection | -10~+65℃ |
charge temperature protection | 0~+60℃ | |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L60*W55 *T9.5mm | ||
NTC:10K NTC Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method: / |