BMS/PCM with Communications Model: AY-LX3S1.5A-T002-LB3S1.5A Ver: A Test item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C Voltage Charging voltage DC:12.6V CC/CV(4.2V/Cell)3S Supply Current Normal operating mode Self consumption current ※ ≤ 30uA Maximal continuous charging current 2A Maximal continuous discharging current 2A Over-charge Protection(single cell) Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.8±0.05V Over discharge detection delay time ※ 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge Over current detection current ※ 15±3A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature High temperature discharge protection 70±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L127.5*W16*T4 mm NTC: / Temperature switch: 70 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: AY-LX3S1.5A-T002-LB3S1.5A | Ver: A | |
Test item (Test at normal temperature 25±2℃) | Criterion | |
Communication Interface | I2C | |
Voltage | Charging voltage | DC:12.6V CC/CV(4.2V/Cell)3S |
Supply Current | Normal operating mode Self consumption current ※ | ≤ 30uA |
Maximal continuous charging current | 2A | |
Maximal continuous discharging current | 2A | |
Over-charge Protection (single cell) | Over charge detection voltage ※ | 4.25±0.05V |
Over charge detection delay time ※ | 0.5S—2S | |
Over charge release voltage | 4.05±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage ※ | 2.8±0.05V |
Over discharge detection delay time ※ | 10—200mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | Discharge Over current detection current ※ | 15±3A |
Detection delay time ※ | 5ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition ☆ | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 30mΩ |
Temperature | High temperature discharge protection | 70±3℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L127.5*W16*T4 mm | ||
NTC: / Temperature switch: 70 ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |