AY-CX4S100A-H120 BMS for lithium batteries - AYAA TECHNOLOGY CO., LTD

AY-CX4S100A-H120(LI-3S10A) Model: AY-CX4S100A-H120 (LI-3S10A) Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Communication Interface RS485/BLE Voltage Charging voltage DC: 12.6V CC/CV(4.2v/Cell)3S Supply Current Maximal continuous charging current 10A Maximal continuous discharging current 10A Current consume in normal operation ≤20mA Current consume in sleep operation ≤1mA Balanced Balance voltage for single cell 4.0±0.05V(Adjustable) Balance current for single cell 42±10mA Turn on the pressure difference 20mV(Adjustable) Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V(Adjustable) Over charge detection delay time 1.0S(Adjustable) Over charge release voltage 4.15±0.05V(Adjustable) Over-discharge protection(single cell) Over discharge detection voltage 2.7±0.05V(Adjustable) Over discharge detection delay time 1.0S(Adjustable) Over discharge release voltage 3.0±0.05V(Adjustable) Charge Over current protection Charge over current detection current 15±2A(Adjustable) Detection delay time 1.0S(Adjustable) Release conditions Removing charger release Discharge Over current protection Discharge over current detection current 1 20±2A(Adjustable) Detection delay time 1 3.0S(Adjustable) Discharge over current detection current 2 30±2A(Adjustable) Detection delay time 2 1.0S(Adjustable) Release conditions Removing the load is lifted Short protection Detection condition Battery B + Short Circuit for P-Connection Head Detection delay time 400uS Release condition Remove load release SOC accuracy(It takes a charge-discharge cycle to achieve the accuracy requirement after initial power-on.) ≤3% Temperature Low temp. protection when charge ... - AYAA TECHNOLOGY CO., LTD

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries
  • AY-CX4S100A-H120 BMS for lithium batteries

AY-CX4S100A-H120 BMS for lithium batteries

  • Model: AY-CX4S100A-H120(LI-3S10A)
  • Maximal continuous discharging current: 10A
  • Size : L120*W70*T14 mm
  • Balancing: YES
  • Battery Series: 3S
Inquire Online Download
Parameter information Product Detail

AY-CX4S100A-H120(LI-3S10A)

Model: AY-CX4S100A-H120 (LI-3S10A) Ver: A
Test item(Test at normal temperature 25±2℃ )Criterion
Communication InterfaceRS485/BLE
VoltageCharging voltageDC: 12.6V CC/CV
(4.2v/Cell)3S
Supply CurrentMaximal continuous charging current10A
Maximal continuous discharging current10A
Current consume in normal operation≤20mA
Current consume in sleep operation≤1mA
BalancedBalance voltage for single cell4.0±0.05V(Adjustable)
Balance current for single cell42±10mA
Turn on the pressure difference20mV(Adjustable)
Over-charge Protection
(single cell)
Over charge detection voltage4.25±0.05V(Adjustable)
Over charge detection delay time1.0S(Adjustable)
Over charge release voltage4.15±0.05V(Adjustable)
Over-discharge protection
(single cell)
Over discharge detection voltage2.7±0.05V(Adjustable)
Over discharge detection delay time1.0S(Adjustable)
Over discharge release voltage3.0±0.05V(Adjustable)
Charge Over current protectionCharge over current detection current15±2A(Adjustable)
Detection delay time1.0S(Adjustable)
Release conditionsRemoving charger release
Discharge Over current protectionDischarge over current detection current 120±2A(Adjustable)
Detection delay time 13.0S(Adjustable)
Discharge over current detection current 230±2A(Adjustable)
Detection delay time 21.0S(Adjustable)
Release conditionsRemoving the load is lifted
Short protectionDetection conditionBattery B + Short Circuit for P-Connection Head
Detection delay time400uS
Release conditionRemove load release
SOCaccuracy(It takes a charge-discharge cycle to achieve the accuracy requirement after initial power-on.)≤3%
TemperatureLow temp. protection when charge-20℃(Adjustable)
Release temp. ( low temp. protection)-15℃(Adjustable)
Over temp. protection when charge55℃(Adjustable)
Release temp. ( over temp. protection)50℃(Adjustable)
Low temp. protection when discharge-40℃(Adjustable)
Release temp. ( low temp. protection)-35℃(Adjustable)
Over temp. protection when discharge70℃(Adjustable)
Release temp. (over temp. protection)65℃(Adjustable)
Operating Temperature Range-40~+85℃
Storage Temperature Range-40~+125℃
SIZE: L120 * W70 * T14 mm
NTC: 10KΩ Temperature switch: /℃ (the batteries temperature) Heart: Yes Weak current switch: Yes Activation Method: /

Chat With Us

Leave Your Message

  • Message