PCM-LB07S20A-AY026V4 Model: PCM-LB07S20A-AY026V4 (LF-6S10A) Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC: 21.6V CC/CV(3.6v/Cell)6S Supply Current Normal current consumption ≤30uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance Balance current for single cell 36±10mA Balance voltage for single cell 3.50±0.05V Over-charge Protection(single cell) Over charge detection voltage 3.65±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.55±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.3±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.7±0.1V Current protection(Battery pack) Discharge over current detection current 30±5A Detection delay time 5mS—20mS Release condition Cut load,AutoRecovery Short protection Detection condition Exterior short circuit Detection delay time 200-600uS Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature High temperature discharge protection 75℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L65 * W40 * T7 mm NTC: 10K NTC cut off 75 ℃ Temperature switch: / ℃ (the batteries temperature) Weak current switch: / Activation Method: / - AYAA TECHNOLOGY CO., LTD
Model: PCM-LB07S20A-AY026V4 (LF-6S10A) Ver: A | ||||||||
Test | item(Test at normal temperature 25±2℃ ) | Criterion | ||||||
Voltage | Charging voltage | DC: 21.6V CC/CV (3.6v/Cell)6S | ||||||
Supply Current | Normal current consumption | ≤30uA | ||||||
Maximal continuous charging current | 10A | |||||||
Maximal continuous discharging current | 10A | |||||||
Balance | Balance current for single cell | 36±10mA | ||||||
Balance voltage for single cell | 3.50±0.05V | |||||||
Over-charge Protection (single cell) | Over charge detection voltage | 3.65±0.05V | ||||||
Over charge detection delay time | 0.5S—2S | |||||||
Over charge release voltage | 3.55±0.1V | |||||||
Over discharge protection (single cell) | Over discharge detection voltage | 2.3±0.05V | ||||||
Over discharge detection delay time | 10—200mS | |||||||
Over discharge release voltage | 2.7±0.1V | |||||||
Current protection (Battery pack) | Discharge over current detection current | 30±5A | ||||||
Detection delay time | 5mS—20mS | |||||||
Release condition | Cut load,Auto Recovery | |||||||
Short protection | Detection condition | Exterior short circuit | ||||||
Detection delay time | 200-600uS | |||||||
Release condition | Cut load | |||||||
Resistance | Main loop electrify resistance | ≤30mΩ | ||||||
Temperature | High temperature discharge protection | 75℃ | ||||||
Operating Temperature Range | -40~+85℃ | |||||||
Storage Temperature Range | -40~+125℃ | |||||||
SIZE: L65 * W40 * T7 mm | ||||||||
NTC: 10K NTC cut off 75 ℃ | Temperature switch: / ℃ (the batteries temperature) | Weak current switch: / | Activation Method: / |