PCM for 3S-4S PCM-LX4S5A-AY186(4S7A) Model: PCM-LX4S5A-AY186 ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4S Supply Current Normal operating mode Self consumption current ※ ≤ 50uA Maximal continuous charging current 7A Maximal continuous discharging current 7A Balance current for single cell ※ / Over-charge Protection(single cell) Balance voltage for single cell ※ / Over charge detection voltage ※ 4.25±0.05V Over charge detection delay time ※ 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage ※ 2.7±0.05V Over discharge detection delay time ※ 10—300mS Over discharge release voltage 3.0±0.1V Current protection (Battery pack) Discharge Over current detection current ※ 15±3A Detection delay time ※ 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition ☆ Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection /℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L65*W48*T5 mm NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-LX4S5A-AY186 | ver: A | |
Test item(Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2v/Cell)4S |
Supply Current | Normal operating mode Self consumption current ※ | ≤ 50uA |
Maximal continuous charging current | 7A | |
Maximal continuous discharging current | 7A | |
Balance current for single cell ※ | / | |
Over-charge Protection (single cell) | Balance voltage for single cell ※ | / |
Over charge detection voltage ※ | 4.25±0.05V | |
Over charge detection delay time ※ | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage ※ | 2.7±0.05V |
Over discharge detection delay time ※ | 10—300mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | Discharge Over current detection current ※ | 15±3A |
Detection delay time ※ | 5ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition ☆ | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | /℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L65*W48*T5 mm | ||
NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |