PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage - AYAA TECHNOLOGY CO., LTD

Smart Battery Managment with Fuel Guage Model: PCM-L04S30-G28+PCM-IICUART-E99 (LF-4S20A) ver: A Test item (Test at normal temperature 25±2℃) Criterion Communication Interface RS232 Voltage Charging voltage DC:14.4V CC/CV(3.6V/Cell)4S Capacity Designing battery capacity(PCM) /mAh Max capacity(Battery pack) /mAh Gas gauge algorithm IT Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤600uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 36mA±10mA Over-charge Protection(single cell) Balance voltage for single cell 3.55V±0.025V Over charge detection voltage 3.90±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.50±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.00±0.07V Over discharge detection delay time 0.5S—2S Over discharge release voltage 2.50±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 40±10A Detection delay time 200-600us Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Discharge temperature detection delay time 5s high temperature discharge recover protection 45℃ high temperature charge protection 65℃ Charge temperature detection delay time 5s high temperature charge recover protection 45℃ Operating ... - AYAA TECHNOLOGY CO., LTD

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage
  • PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage

PCM-L04S30-G28+PCM-IICUART-E99 (4S 30A) Smart Battery Managment with Fuel Guage

  • Model: PCM-L04S30-G28+PCM-IICUART-E99  
  • Working Current: 30A
  • Size: L80*W60*T8 mm
  • Battery Type: Li-ion/LiFePO4
  • Battery Series: 4S
Inquire Online Download
Parameter information Product Detail

Smart Battery Managment with Fuel Guage

Model: PCM-L04S30-G28+PCM-IICUART-E99 (LF-4S20A) ver: A
Test item (Test at normal temperature 25±2℃)Criterion
Communication Interface RS232
VoltageCharging voltageDC:14.4V CC/CV(3.6V/Cell)4S
CapacityDesigning battery capacity(PCM)/mAh
Max capacity(Battery pack)/mAh
Gas gauge algorithmIT
Supply CurrentNormal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current≤600uA
Maximal continuous charging current20A
Maximal continuous discharging current20A
Balance current for single cell36mA±10mA
Over-charge Protection
(single cell)
Balance voltage for single cell3.55V±0.025V
Over charge detection voltage3.90±0.05V
Over charge detection delay time0.5S—2S
Over charge release voltage3.50±0.05V
Over discharge protection
(single cell)
Over discharge detection voltage2.00±0.07V
Over discharge detection delay time0.5S—2S
Over discharge release voltage2.50±0.1V
Current protection
(Battery pack)
ChargeOver current detection current/
Detection delay time/
Discharge Over current detection current40±10A
Detection delay time200-600us
Release conditionCut load, Auto Recovery
Short protectionDetection conditionExterior short circuit
Detection delay time200-600us
Release conditionCut load
ResistanceMain loop electrify resistance≤20mΩ
Temperaturehigh temperature discharge protection65℃
Discharge temperature detection delay time5s
high temperature discharge recover protection45℃
high temperature charge protection65℃
Charge temperature detection delay time5s
high temperature charge recover protection45℃
Operating Temperature Range-20~+85℃
Storage Temperature Range-40~+125℃
SIZE: L80*W60*T8mm