PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage - AYAA TECHNOLOGY CO., LTD

Smart Battery Managment with Fuel Guage Protection Circuit Module Specifications For 12.8V LiFePO4 Battery Pack Model:PCM-L04S100-G09 (LF-4S) No. Test item (Test at normal temperature 25±2℃ and relative humidity≤90%) Criterion 1 Communication Interface SMBUS 2 Capacity Designing battery capacity(PCM ) mAh Max capacity(Battery pack) 100000mAh Capacity design multiple(Battery pack) 10 Times External capacity Indication LCD,LED Gas gauge algorithm IT (High accuracy) 3 Voltage Charging voltage DC: 14.4V CC/CV(3.6V/1cell) Cell-balance release voltage 3.6V ±0.025V Cell-balance detection delay time 0.5S—2S 4 Current Balance current for single cell 57±10mA Current self-consumption for single cell ≤30μA Normal operating-mode current self-consumption(Gas Gauge IC) 600 uA Low current self-consumption-mode (Gas Gauge IC) 350 uA SMBUS Communicating-mode current self-consumption(Gas Gauge IC) ≤2mA Bluetooth mode current self-consumption(Gas Gauge IC) ≤50mA Maximal continuous charging current 100A Maximal continuous discharging current 100A 5 Over charge Protection Over charge detection voltage 3.75±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 3.50±0.05V 6 Over discharge protection Over discharge detection voltage 2.20±0.05V Over discharge detection delay time 10—30mS Over discharge release voltage 2.50±0.05V 7 Over current protection Over charge detection current 150±20A detection delay time 2s Over current detection current 300±50A Detection delay time 5s Release condition Cut load, auro-release 8 Short ... - AYAA TECHNOLOGY CO., LTD

INQUIRY NOW LINKEDIN FACEBOOK YOUTUBE
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage
  • PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage

PCM-L04S100-G09 (4S 100A) Smart Battery Managment with Fuel Guage

  • Model: PCM-L04S100-G09
  • Working Current: 100A
  • Size:  L250*W120*T18mm
  • Battery Type: Li-ion/LiFePO4
  • Battery Series: 4S
Inquire Online Download
Parameter information Product Detail

Smart Battery Managment with Fuel Guage

Protection Circuit Module Specifications For 12.8V LiFePO4 Battery Pack
Model:PCM-L04S100-G09 (LF-4S)
No. Test item
(Test at normal temperature 25±2℃ and relative humidity≤90%)
Criterion
1Communication Interface SMBUS
2CapacityDesigning battery capacity(PCM ) mAh
Max capacity(Battery pack) 100000mAh
Capacity design multiple(Battery pack)10 Times
External capacity Indication LCD,LED
Gas gauge algorithm IT (High accuracy)
3VoltageCharging voltage DC: 14.4V CC/CV(3.6V/1cell)
Cell-balance release voltage 3.6V ±0.025V
Cell-balance detection delay time 0.5S—2S
4Current Balance current for single cell 57±10mA
Current self-consumption for single cell ≤30μA
Normal operating-mode current self-consumption(Gas Gauge IC)600 uA
Low current self-consumption-mode (Gas Gauge IC)350 uA
SMBUS Communicating-mode current self-consumption(Gas Gauge IC) ≤2mA
Bluetooth mode current self-consumption(Gas Gauge IC)≤50mA
Maximal continuous charging current100A
Maximal continuous discharging current 100A
5Over charge Protection Over charge detection voltage3.75±0.05V
Over charge detection delay time 0.5S—2S
Over charge release voltage3.50±0.05V
6Over discharge protection Over discharge detection voltage 2.20±0.05V
Over discharge detection delay time 10—30mS
Over discharge release voltage2.50±0.05V
7Over current protection Over charge detection current150±20A
detection delay time 2s
Over current detection current 300±50A
Detection delay time5s
Release conditionCut load, auro-release
8Short circuit protection Detection condition Exterior short circuit
Detection delay time200-800us
Release condition Cut load, auro-release
9ResistanceProtection circuitry (MOSFET)≤30mΩ
10TemperatureOperating Temperature Range -40~+85℃
Storage Temperature Range-40~+125℃
Charging Temperature Protection 60℃
Discharging Temperature Protection65℃
MOSFET Temperature Protection95℃
Charging under Temperature Protection 0±3℃
Discharging under Temperature Protection -20±3℃
11Heating functionLow temperature heating start threshold≤0℃±3℃
Low temperature heating stop threshold≥5℃±3℃