PCM for 3S-4S Model: PCM-L04S12-144(LI-4S10A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:16.8V CC/CV(4.2v/Cell)4s Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell / Over-charge Protection (single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.5±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 25±5A Detection delay time 5ms—50ms Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 60mΩ Temperature high temperature discharge protection /℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: 40*40*3.5mm NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L04S12-144(LI-4S10A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:16.8V CC/CV(4.2v/Cell)4s |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤30uA |
Maximal continuous charging current | 10A | |
Maximal continuous discharging current | 10A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.5±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 25±5A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 60mΩ |
Temperature | high temperature discharge protection | /℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: 40*40*3.5mm | ||
NTC: / Temperature switch: / ℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |