PCM for 1S-2S PCM-LX2S2A-AY321 (LI-2S2A) Model: PCM-LX2S2A-AY321 (LI-2S2A) Ver: A Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 8.4V CC/CV (4.2V/Cell) 2s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤10uA Maximal continuous charging current 2A Maximal continuous discharging current 2A Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.05±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.4±0.05V Over discharge detection delay time 100—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 5±2A Detection delay time 5ms—20ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 65mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L34*W17*T3 mm P+/P- 2 contacts on top 12mm diameter “hard gold” NTC: / Temperature switch: / Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-LX2S2A-AY321 (LI-2S2A) Ver: A | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC: 8.4V CC/CV (4.2V/Cell) 2s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤10uA |
Maximal continuous charging current | 2A | |
Maximal continuous discharging current | 2A | |
Over-charge Protection (single cell) | Over charge detection voltage | 4.25±0.05V |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.05±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.4±0.05V |
Over discharge detection delay time | 100—200mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 5±2A | |
Detection delay time | 5ms—20ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 65mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE: L34*W17*T3 mm P+/P- 2 contacts on top 12mm diameter “hard gold” | ||
NTC: / Temperature switch: / Weak current switch:/ Activation Method:/ |