PCM for 3S-4S PCM-LB4S80A-AY143 (LF-4S80A) Model: PCM-LB4S80A-AY143 (LF-4S80A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:14.4V CC/CV(3.6V/Cell)4s Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 80A Maximal continuous discharging current 80A Balance current for single cell 36±10mA Over-charge Protection(single cell) Balance voltage for single cell 3.6V±0.05V Over charge detection voltage 3.9±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 3.8±0.025V Over discharge protection(single cell) Over discharge detection voltage 2.0±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 2.50±0.05V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 250±30A Detection delay time 10ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 100-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65±10℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L135*W95*T8.5 mm NTC: / Temperature switch:/ Weak current switch:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-LB4S80A-AY143 (LF-4S80A) ver: A | ||
Test item(Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:14.4V CC/CV(3.6V/Cell)4s |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 80A | |
Maximal continuous discharging current | 80A | |
Balance current for single cell | 36±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 3.6V±0.05V |
Over charge detection voltage | 3.9±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 3.8±0.025V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.0±0.05V |
Over discharge detection delay time | 10—200mS | |
Over discharge release voltage | 2.50±0.05V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 250±30A | |
Detection delay time | 10ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 100-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | 65±10℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L135*W95*T8.5 mm | ||
NTC: / Temperature switch:/ Weak current switch:/ |