PCM-L05S100A-AY073 Model: PCM-L05S100A-AY073 (LI-5S80A) Ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC: 21V CC/CV(4.2v/Cell)5S Supply Current Normal current consumption ≤50uA Maximal continuous charging current 80A Maximal continuous discharging current 80A Balance Balance current for single cell 42±10mA Balance voltage for single cell 4.2±0.05V Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over-discharge Protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 10—200mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) Discharge over current detection current 300±50A Detection delay time 5mS—50mS Release condition Cut load,AutoRecovery Short protection Detection condition Exterior short circuit Detection delay time 200-600uS Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature High temperature discharge protection 65±3℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120 * W60 * T18 mm NTC: / Temperature switch: 65 ℃ (the batteries temperature) Weak current switch: / Activation Method: / - AYAA TECHNOLOGY CO., LTD
Model: PCM-L05S100A-AY073 (LI-5S80A) | Ver: A | ||||
Test item(Test at normal temperature 25±2℃ ) | Criterion | ||||
Voltage | Charging voltage | DC: 21V CC/CV (4.2v/Cell)5S | |||
Supply Current | Normal current consumption | ≤50uA | |||
Maximal continuous charging current | 80A | ||||
Maximal continuous discharging current | 80A | ||||
Balance | Balance current for single cell | 42±10mA | |||
Balance voltage for single cell | 4.2±0.05V | ||||
Over-charge Protection (single cell) | Over charge detection voltage | 4.25±0.05V | |||
Over charge detection delay time | 0.5S—2S | ||||
Over charge release voltage | 4.10±0.1V | ||||
Over-discharge Protection (single cell) | Over discharge detection voltage | 2.8±0.05V | |||
Over discharge detection delay time | 10—200mS | ||||
Over discharge release voltage | 3.0±0.1V | ||||
Current protection (Battery pack) | Discharge over current detection current | 300±50A | |||
Detection delay time | 5mS—50mS | ||||
Release condition | Cut load,Auto Recovery | ||||
Short protection | Detection condition | Exterior short circuit | |||
Detection delay time | 200-600uS | ||||
Release condition | Cut load | ||||
Resistance | Main loop electrify resistance | ≤30mΩ | |||
Temperature | High temperature discharge protection | 65±3℃ | |||
Operating Temperature Range | -40~+85℃ | ||||
Storage Temperature Range | -40~+125℃ | ||||
SIZE: L120 * W60 * T18 mm | |||||
NTC: / | Temperature switch: 65 ℃ (the batteries temperature) | Weak current switch: / | Activation Method: / |