BMS/PCM with Fuel Gauge Model: AY-LB7S10A-T004-LB7S10A Ver: A Test Item (Test at normal temperature 25±2℃) Criterion Communication Interface I2C BQ34Z100 Voltage Charging voltage DC:29.4V CC/CV(4.2V/Cell)7s Capacity Designing battery capacity(PCM) 10Ah Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤160uA Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current ≤80uA Maximal continuous charging current 10A Maximal continuous discharging current 10A Balance current for single cell 84±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.28±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.10±0.1V Over discharge protection(single cell) Over discharge detection voltage 3.0±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.2±0.1V Current protection(Battery pack) Discharge Over current detection current 50±10A Detection delay time 0.5S—2S Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 20mΩ Temperature Temperature protection +65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L100*W65*T8mm LED SIZE: 30*16*3 (6) NTC: 10KNTC B=3435 Temperature switch:/℃ (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: AY-LB7S10A-T004-LB7S10A Ver: A | ||
Test Item (Test at normal temperature 25±2℃) | Criterion | |
Communication Interface | I2C BQ34Z100 | |
Voltage | Charging voltage | DC:29.4V CC/CV(4.2V/Cell)7s |
Capacity | Designing battery capacity(PCM) | 10Ah |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤160uA |
Low-power operating mode current:Fuel gauge in FULLSLEEP mode.ILOAD < Sleep Current | ≤80uA | |
Maximal continuous charging current | 10A | |
Maximal continuous discharging current | 10A | |
Balance current for single cell | 84±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.28±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.10±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 3.0±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.2±0.1V | |
Current protection (Battery pack) | Discharge Over current detection current | 50±10A |
Detection delay time | 0.5S—2S | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 20mΩ |
Temperature | Temperature protection | +65℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L100*W65*T8mm LED SIZE: 30*16*3 (6) | ||
NTC: 10KNTC B=3435 Temperature switch:/℃ (the batteries temperature) Weak current switch:/ Activation Method:/ |