PCM for 5S-9S PCM-L05S60-F91 LI-5S50A Model: PCM-L05S60-F91(5S) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:21V CC/CV(4.2v/Cell)5s Capacity Designing battery capacity(PCM) 5200mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 60A Maximal continuous discharging current 60A Balance current for single cell 68±10mA Over-charge Protection(single cell) Balance voltage for single cell 4.2V±0.05V Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±20A Detection delay time 50ms—200ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L120*W65*T11 mm NTC: / Temperature switch:90℃/65℃ Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L05S60-F91(5S) ver: A | ||
Test item(Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:21V CC/CV(4.2v/Cell)5s |
Capacity | Designing battery capacity(PCM) | 5200mAh |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 60A | |
Maximal continuous discharging current | 60A | |
Balance current for single cell | 68±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.05V |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.75±0.1V |
Over discharge detection delay time | 150—300mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 150±20A | |
Detection delay time | 50ms—200ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤30mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE: L120*W65*T11 mm | ||
NTC: / Temperature switch:90℃/65℃ Weak current switch:/ Activation Method:/ |