PCM for 3S-4SS PCM-L03C03-D13 LI-3S 3A Model: PCM-L03C03-D13 (3S) Test item (Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC: 12.6V CC/CV(4.2v/Cell)3s Capacity Designing battery capacity (PCM) / Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤30uA Maximal continuous charging current 3A Maximal continuous discharging current 3A Balance current for single cell / Over-charge Protection(single cell) Balance voltage for single cell / Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.75±0.1V Over discharge detection delay time 150—300mS Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 10±2A Detection delay time 50ms—150ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-800us Release condition Cut load Resistance Main loop electrify resistance ≤30mΩ Temperature Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L18*W18*T3.8 mm NTC: 10K Temperature switch:/ Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L03C03-D13 (3S) | ||
Test item (Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC: 12.6V CC/CV(4.2v/Cell)3s |
Capacity | Designing battery capacity (PCM) | / |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤30uA |
Maximal continuous charging current | 3A | |
Maximal continuous discharging current | 3A | |
Balance current for single cell | / | |
Over-charge Protection (single cell) | Balance voltage for single cell | / |
Over charge detection voltage | 4.25±0.05V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.75±0.1V |
Over discharge detection delay time | 150—300mS | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 10±2A | |
Detection delay time | 50ms—150ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-800us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤30mΩ |
Temperature | Operating Temperature Range | -40~+85℃ |
Storage Temperature Range | -40~+125℃ | |
SIZE: L18*W18*T3.8 mm | ||
NTC: 10K Temperature switch:/ Weak current switch:/ Activation Method:/ |