PCM for 10S-16S Model: PCM-L16S25-591(Li-16S20A) ver: A Test item(Test at normal temperature 25±2℃ ) Criterion Voltage Charging voltage DC:67.2V CC/CV(4.2V/Cell)16S Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 20A Maximal continuous discharging current 20A Balance current for single cell 68±10mA Over-charge Protection (single cell) Balance voltage for single cell 4.2V±0.025V Over charge detection voltage 4.25±0.025V Over charge detection delay time 0.5S—2S Over charge release voltage 4.15±0.05V Over discharge protection(single cell) Over discharge detection voltage 2.50±0.07V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 80±10A Detection delay time 200-600us Release condition Cut load,Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤20mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L78*W55*T18mm NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-L16S25-591(Li-16S20A) ver: A | ||
Test item(Test at normal temperature 25±2℃ ) | Criterion | |
Voltage | Charging voltage | DC:67.2V CC/CV(4.2V/Cell)16S |
Capacity | Designing battery capacity(PCM) | /mAh |
Supply Current | Normal operating mode current:Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 20A | |
Maximal continuous discharging current | 20A | |
Balance current for single cell | 68±10mA | |
Over-charge Protection (single cell) | Balance voltage for single cell | 4.2V±0.025V |
Over charge detection voltage | 4.25±0.025V | |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.15±0.05V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.50±0.07V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 80±10A | |
Detection delay time | 200-600us | |
Release condition | Cut load,Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤20mΩ |
Temperature | high temperature discharge protection | 65℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L78*W55*T18mm | ||
NTC: / Temperature switch: / (the batteries temperature) Weak current switch:/ Activation Method:/ |