PCM for 10S-16S Model: PCM-LX16S35A-AY215(LI-16S50A) ver: A Test item(Test at normal temperature 25±2℃) Criterion Voltage Charging voltage DC:67.2V CC/CV(4.2v/Cell)16s Capacity Designing battery capacity(PCM) /mAh Supply Current Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current ≤50uA Maximal continuous charging current 50A Maximal continuous discharging current 50A Over-charge Protection(single cell) Over charge detection voltage 4.25±0.05V Over charge detection delay time 0.5S—2S Over charge release voltage 4.1±0.1V Over discharge protection(single cell) Over discharge detection voltage 2.8±0.05V Over discharge detection delay time 0.5S—2S Over discharge release voltage 3.0±0.1V Current protection(Battery pack) ChargeOver current detection current / Detection delay time / Discharge Over current detection current 150±30A Detection delay time 5ms—50ms Release condition Cut load, Auto Recovery Short protection Detection condition Exterior short circuit Detection delay time 200-600us Release condition Cut load Resistance Main loop electrify resistance ≤ 30mΩ Temperature high temperature discharge protection 65℃ Operating Temperature Range -40~+85℃ Storage Temperature Range -40~+125℃ SIZE: L100*W58*T13 mm NTC: / Temperature switch:65℃ Weak current switch:/ Activation Method:/ - AYAA TECHNOLOGY CO., LTD
Model: PCM-LX16S35A-AY215(LI-16S50A) ver: A | ||
Test item(Test at normal temperature 25±2℃) | Criterion | |
Voltage | Charging voltage | DC:67.2V CC/CV(4.2v/Cell)16s |
Capacity | Designing battery capacity(PCM) | /mAh |
Supply Current | Normal operating mode current: Fuel gauge in NORMAL mode. ILOAD >Sleep Current | ≤50uA |
Maximal continuous charging current | 50A | |
Maximal continuous discharging current | 50A | |
Over-charge Protection (single cell) | Over charge detection voltage | 4.25±0.05V |
Over charge detection delay time | 0.5S—2S | |
Over charge release voltage | 4.1±0.1V | |
Over discharge protection (single cell) | Over discharge detection voltage | 2.8±0.05V |
Over discharge detection delay time | 0.5S—2S | |
Over discharge release voltage | 3.0±0.1V | |
Current protection (Battery pack) | ChargeOver current detection current | / |
Detection delay time | / | |
Discharge Over current detection current | 150±30A | |
Detection delay time | 5ms—50ms | |
Release condition | Cut load, Auto Recovery | |
Short protection | Detection condition | Exterior short circuit |
Detection delay time | 200-600us | |
Release condition | Cut load | |
Resistance | Main loop electrify resistance | ≤ 30mΩ |
Temperature | high temperature discharge protection | 65℃ |
Operating Temperature Range | -40~+85℃ | |
Storage Temperature Range | -40~+125℃ | |
SIZE: L100*W58*T13 mm | ||
NTC: / Temperature switch:65℃ Weak current switch:/ Activation Method:/ |